costream: A Streaming Evaluation Protocol for Wearable Fall Detection
首次提交 2025-09-15 19:19
版本更新 2026-11-12 21:27
雷达观测 2026-11-13 14:15
摘要
Wearable fall detectors are commonly evaluated on presegmented windows, where a fall window is extracted at an annotated impact and non-fall windows are sampled from fall-free signal. However, a deployed detector processes a continuous sensor stream in which the location of a fall is unknown. We specify a streaming evaluation protocol in which a detector traverses an unsegmented recording, aggregates window-level scores into a temporal confidence map, and emits timestamped events that are evaluated against the annotated fall. Holding the dataset, participant-wise splits, window construction and fitted models fixed, we compare presegmented and streaming evaluation on clinically verified real-world falls. The two protocols identify the same best-performing method overall, but select different methods in 6 of 20 model-window configurations, with the divergence associated with differences in the temporal clustering of false alarms. Streaming evaluation also exposes deployment-relevant quantities, including false alarm rate over elapsed monitoring time, detection delay, and the effect of the decision threshold, that are not captured by per-window evaluation. These results show that evaluation protocol can materially affect conclusions about wearable fall detectors and should be considered when assessing their suitability for continuous monitoring.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v2 · 2026-11-12 21:27 · 最新观测版本
costream: A Streaming Evaluation Protocol for Wearable Fall Detection
Wearable fall detectors are commonly evaluated on presegmented windows, where a fall window is extracted at an annotated impact and non-fall windows are sampled from fall-free signal. However, a deployed detector processes a continuous sensor stream in which the location of a fall is unknown. We specify a streaming evaluation protocol in which a detector traverses an unsegmented recording, aggregates window-level scores into a temporal confidence map, and emits timestamped events that are evaluated against the annotated fall. Holding the dataset, participant-wise splits, window construction and fitted models fixed, we compare presegmented and streaming evaluation on clinically verified real-world falls. The two protocols identify the same best-performing method overall, but select different methods in 6 of 20 model-window configurations, with the divergence associated with differences in the temporal clustering of false alarms. Streaming evaluation also exposes deployment-relevant quantities, including false alarm rate over elapsed monitoring time, detection delay, and the effect of the decision threshold, that are not captured by per-window evaluation. These results show that evaluation protocol can materially affect conclusions about wearable fall detectors and should be considered when assessing their suitability for continuous monitoring.
查看此版本解读 →查看此版本原文 ↗