Coordinated Cooling and Compute Management for AI Datacenters

首次提交 2026-01-13 09:07
版本更新 2026-11-13 13:39
雷达观测 2026-11-17 04:57
arXiv ↗PDF ↗

摘要

The AI datacenters are currently being deployed on a large scale to support the training and deployment of power-intensive large-language models (LLMs). Extensive amount of computation and cooling required in datacenters increase concerns about the energy use and carbon emissions of AI datacenters. Although current state-of-the-art has examined the energy efficiency of LLM inference, most prior research focused on optimizing compute-side scheduling without considering thermal objectives or constraints. Since GPU-intensive inference generates substantial heat that can degrade datacenter performance, ignoring thermal effects can increase total energy consumption and reduce the efficiency of LLM serving. To fill this gap, we profile the characteristics of GPU servers under varying cooling and AI jobs, and develop a joint cooling and computing modeling approach for AI datacenters. Built upon such workload and thermal dynamics models, a novel hierarchical control framework is proposed to co-optimize computing and thermal management by identifying the optimal GPU parallelism, frequency (DVFS), and cooling control knobs. Using real Azure inference traces and detailed GPU profiling, our model balances serving latency and thermal constraints in AI datacenters while significantly improving AI datacenters' energy efficiency.

作者备注:Accepted at IEEE Transactions on Cloud Computing

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-13 13:39 · 最新观测版本

Coordinated Cooling and Compute Management for AI Datacenters

The AI datacenters are currently being deployed on a large scale to support the training and deployment of power-intensive large-language models (LLMs). Extensive amount of computation and cooling required in datacenters increase concerns about the energy use and carbon emissions of AI datacenters. Although current state-of-the-art has examined the energy efficiency of LLM inference, most prior research focused on optimizing compute-side scheduling without considering thermal objectives or constraints. Since GPU-intensive inference generates substantial heat that can degrade datacenter performance, ignoring thermal effects can increase total energy consumption and reduce the efficiency of LLM serving. To fill this gap, we profile the characteristics of GPU servers under varying cooling and AI jobs, and develop a joint cooling and computing modeling approach for AI datacenters. Built upon such workload and thermal dynamics models, a novel hierarchical control framework is proposed to co-optimize computing and thermal management by identifying the optimal GPU parallelism, frequency (DVFS), and cooling control knobs. Using real Azure inference traces and detailed GPU profiling, our model balances serving latency and thermal constraints in AI datacenters while significantly improving AI datacenters' energy efficiency.

查看此版本解读 →查看此版本原文 ↗