Dynamic Load Model for Data Centers with Pattern-Consistent Calibration

首次提交 2026-02-08 16:15
版本更新 2026-11-16 12:34
雷达观测 2026-11-17 17:12
arXiv ↗PDF ↗

摘要

The rapid growth of large-scale data centers has made accurate dynamic data center load modeling increasingly important for power system analysis. Such loads are characterized by fast workload-driven variability and protection-driven disconnection and reconnection behavior that are not captured by conventional load models. Existing approaches to data center load modeling include physics-based methods, which provide interpretable structure for grid simulation, and data-driven approaches, which capture empirical workload variability from data. However, physics-based models are typically uncalibrated to facility-level operation, while trajectory alignment in data-driven methods often leads to overfitting and unrealistic dynamic behavior. To resolve these limitations, we design the framework to leverage both physics-based structure and data-driven adaptability. We further show that trajectory-level alignment is limited for inherently stochastic data center loads. Therefore, we design the calibration to align temporal and statistical patterns using temporal contrastive learning (TCL). This calibration is performed locally at the facility, and only calibrated parameters are shared with utilities, reducing the need to share full-resolution operational time-series traces with utilities. The proposed load model is calibrated by real-world operational load data from the MIT Supercloud, ASU Sol, Blue Waters, and ASHRAE datasets. Then it is integrated into the ANDES platform and evaluated on the IEEE 39-bus, NPCC 140-bus, and WECC 179-bus systems. We simulate the collective dynamic responses of multiple heterogeneous data centers under system-level disturbances. We find that interactions among data centers can fundamentally alter post-disturbance recovery behavior, producing compound disconnection-reconnection dynamics and delayed stabilization that are not captured by uncalibrated load models.

作者备注:12 pages, 12 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-16 12:34 · 最新观测版本

Dynamic Load Model for Data Centers with Pattern-Consistent Calibration

The rapid growth of large-scale data centers has made accurate dynamic data center load modeling increasingly important for power system analysis. Such loads are characterized by fast workload-driven variability and protection-driven disconnection and reconnection behavior that are not captured by conventional load models. Existing approaches to data center load modeling include physics-based methods, which provide interpretable structure for grid simulation, and data-driven approaches, which capture empirical workload variability from data. However, physics-based models are typically uncalibrated to facility-level operation, while trajectory alignment in data-driven methods often leads to overfitting and unrealistic dynamic behavior. To resolve these limitations, we design the framework to leverage both physics-based structure and data-driven adaptability. We further show that trajectory-level alignment is limited for inherently stochastic data center loads. Therefore, we design the calibration to align temporal and statistical patterns using temporal contrastive learning (TCL). This calibration is performed locally at the facility, and only calibrated parameters are shared with utilities, reducing the need to share full-resolution operational time-series traces with utilities. The proposed load model is calibrated by real-world operational load data from the MIT Supercloud, ASU Sol, Blue Waters, and ASHRAE datasets. Then it is integrated into the ANDES platform and evaluated on the IEEE 39-bus, NPCC 140-bus, and WECC 179-bus systems. We simulate the collective dynamic responses of multiple heterogeneous data centers under system-level disturbances. We find that interactions among data centers can fundamentally alter post-disturbance recovery behavior, producing compound disconnection-reconnection dynamics and delayed stabilization that are not captured by uncalibrated load models.

查看此版本解读 →查看此版本原文 ↗