← 研踪 PaperTrailarXiv:2606.05487 · v3
VASTO: Simultaneous reconstruction of vascular geometry and blood flow from tomographic projections via differentiable topology optimization
首次提交 2026-06-04 06:18
版本更新 2026-11-07 05:22
雷达观测 2026-11-10 10:11
摘要
Computed Tomography Angiography (CTA) is widely used to reconstruct vascular geometry from projection measurements, with conventional approaches such as Filtered Back-Projection (FBP) and Iterative Reconstruction (IR) forming the clinical standard. Despite recent advances, these methods remain susceptible to sparse and noisy measurement, making accurate recovery of critical anatomical features challenging. This consequently leads to poor estimation of blood flow. In this work, we present a fluid-physics-constrained reconstruction framework that leverages topology optimization (TO) to jointly recover vascular geometry and blood flow directly from time-resolved CTA sinograms. The formulation couples a steady incompressible flow model with a transient advection-diffusion contrast transport model, mapped to sinogram space through a differentiable projection operator. The velocity field is recovered as part of the reconstruction, and thus hemodynamic information can be obtained without requiring a separate computational fluid dynamics pipeline. The proposed method is demonstrated on synthetic phantoms under varying sparsity and noise levels, and on representative projection data.
作者备注:v3: title slightly modified, added three new experimental sections and minor edits
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v3 · 2026-11-07 05:22 · 最新观测版本
VASTO: Simultaneous reconstruction of vascular geometry and blood flow from tomographic projections via differentiable topology optimization
Computed Tomography Angiography (CTA) is widely used to reconstruct vascular geometry from projection measurements, with conventional approaches such as Filtered Back-Projection (FBP) and Iterative Reconstruction (IR) forming the clinical standard. Despite recent advances, these methods remain susceptible to sparse and noisy measurement, making accurate recovery of critical anatomical features challenging. This consequently leads to poor estimation of blood flow. In this work, we present a fluid-physics-constrained reconstruction framework that leverages topology optimization (TO) to jointly recover vascular geometry and blood flow directly from time-resolved CTA sinograms. The formulation couples a steady incompressible flow model with a transient advection-diffusion contrast transport model, mapped to sinogram space through a differentiable projection operator. The velocity field is recovered as part of the reconstruction, and thus hemodynamic information can be obtained without requiring a separate computational fluid dynamics pipeline. The proposed method is demonstrated on synthetic phantoms under varying sparsity and noise levels, and on representative projection data.
查看此版本解读 →查看此版本原文 ↗