摘要
Safe deployment of clinical vision-language models (VLMs) requires reliable uncertainty estimation (UE): a signal indicating when predictions should be trusted or escalated to a clinician. We test whether current UE methods actually deliver this signal. Benchmarking 8 methods across 12 VLMs on clinical visual question-answering (VQA), we find that UE quality is not an intrinsic property of the UE method: it tracks model accuracy, degrading precisely where the model performance is weakest, and therefore where reliability is most needed. When we stress-test models by hiding the correct option among the multiple-choice answers (NOTA perturbations), accuracy collapses while uncertainty barely changes, leaving models systematically miscalibrated. Yet, we find that uncertainty on the unperturbed input reliably anticipates which predictions will collapse under NOTA, indicating that UE in current VLMs carries diagnostic information about model fragility. Our results position UE as a diagnostic tool for identifying fragile predictions and motivate perturbation-based evaluation as a path toward safe clinical deployment.
作者备注:20 pages, 4 figures. Accepted to the Findings of EMNLP 2026
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v3 · 2026-11-17 00:31 · 最新观测版本
Uncertainty Is Not a Safety Net for Clinical VQA, but Can It Anticipate Model Failure?
Safe deployment of clinical vision-language models (VLMs) requires reliable uncertainty estimation (UE): a signal indicating when predictions should be trusted or escalated to a clinician. We test whether current UE methods actually deliver this signal. Benchmarking 8 methods across 12 VLMs on clinical visual question-answering (VQA), we find that UE quality is not an intrinsic property of the UE method: it tracks model accuracy, degrading precisely where the model performance is weakest, and therefore where reliability is most needed. When we stress-test models by hiding the correct option among the multiple-choice answers (NOTA perturbations), accuracy collapses while uncertainty barely changes, leaving models systematically miscalibrated. Yet, we find that uncertainty on the unperturbed input reliably anticipates which predictions will collapse under NOTA, indicating that UE in current VLMs carries diagnostic information about model fragility. Our results position UE as a diagnostic tool for identifying fragile predictions and motivate perturbation-based evaluation as a path toward safe clinical deployment.
查看此版本解读 →查看此版本原文 ↗