跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2607.27741 · v2

Three-Photon Bayesian Imaging of Ortho-Positronium

首次提交 2026-07-30 14:28
版本更新 2026-11-11 14:30
雷达观测 2026-11-13 11:11
arXiv ↗PDF ↗

摘要

PET provides functional images relying on two-photon coincidences from positron-electron annihilation. In human tissue, about 40\% of annihilations are preceded by Ps formation, of which o-Ps component partially decays into three photons, with the remainder annihilating via pick-off or spin-exchange into two photons. This three-photon channel carries additional information about the surrounding micro-environment, including the three-to-two-photon yield ratio as a potential diagnostic marker. We propose the TRIO algorithm, a novel three-photon event-by-event image reconstruction algorithm formulated as a Bayesian maximum a posteriori inference problem. TRIO unifies time-based trilateration, energy-based reconstruction and, for the first time, a physics-informed prior derived from the QED description of Ps decay within a single probabilistic framework. In contrast to positronium lifetime imaging, which requires a prompt photon and is therefore restricted to specific radionuclides, TRIO relies solely on the three photons and is fully compatible with standard radionuclides such as 18F. Monte Carlo simulation modelled after the Siemens Biograph Quadra scanner demonstrates a mean position error of 1.65~cm, improving by a factor of about 2.8 over the time-based trilateration (4.59 cm) and a factor of about 5.3 over energy-based reconstruction alone (8.7 cm). More importantly, the proposed Bayesian approach is compatible with existing TOF-PET scanners that can register three-photon annihilation coincidences.

作者备注:v2:Updated simulation (10% FWHM energy resolution, energy-dependent time resolution, 322 rings). Results and figures revised. 17 pages, 4 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-11 14:30 · 最新观测版本

Three-Photon Bayesian Imaging of Ortho-Positronium

PET provides functional images relying on two-photon coincidences from positron-electron annihilation. In human tissue, about 40\% of annihilations are preceded by Ps formation, of which o-Ps component partially decays into three photons, with the remainder annihilating via pick-off or spin-exchange into two photons. This three-photon channel carries additional information about the surrounding micro-environment, including the three-to-two-photon yield ratio as a potential diagnostic marker. We propose the TRIO algorithm, a novel three-photon event-by-event image reconstruction algorithm formulated as a Bayesian maximum a posteriori inference problem. TRIO unifies time-based trilateration, energy-based reconstruction and, for the first time, a physics-informed prior derived from the QED description of Ps decay within a single probabilistic framework. In contrast to positronium lifetime imaging, which requires a prompt photon and is therefore restricted to specific radionuclides, TRIO relies solely on the three photons and is fully compatible with standard radionuclides such as 18F. Monte Carlo simulation modelled after the Siemens Biograph Quadra scanner demonstrates a mean position error of 1.65~cm, improving by a factor of about 2.8 over the time-based trilateration (4.59 cm) and a factor of about 5.3 over energy-based reconstruction alone (8.7 cm). More importantly, the proposed Bayesian approach is compatible with existing TOF-PET scanners that can register three-photon annihilation coincidences.

查看此版本解读 →查看此版本原文 ↗