An ECG foundation model for zero-shot transfer from hospital to point-of-care devices

首次提交 2026-08-04 21:58
版本更新 2026-11-17 01:01
雷达观测 2026-11-17 16:10
arXiv ↗PDF ↗

摘要

Electrocardiogram (ECG) recording is moving from hospitals to point-of-care devices that record one or two leads, where public labelled data is too scarce to build foundation models (FMs) as for 12-lead ECGs. Whether existing 12-lead FMs transfer to these devices without retraining is unknown. We show that seven published FMs reach a zero-shot AUROC of 41-81% on two real point-of-care datasets and, when reduced to one or two leads, lose 12-35 AUROC points on average and gain 0.15-0.23 in mean absolute error across 29 benchmarks covering 1,673 clinical targets. We present RELAY, a 7-million-parameter FM that represents ECGs as graphs of segments from whichever leads are recorded, without filling missing ones or knowing their identities. Pretrained on 9.2 million 12-lead ECGs, RELAY is competitive with 12 leads, ranks first on both point-of-care datasets (AUROC 87.6% and 81.5%) and on 26 and 22 of 29 benchmarks with one and two random leads, and keeps the most informative operating point when 12-lead thresholds are applied to device recordings. Matched ablations show that omitting absent leads, rather than filling them, reduces what RELAY loses in transfer. ECG FMs should therefore be judged across all the acquisition settings, not on 12-lead benchmarks alone.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-17 01:01 · 最新观测版本

An ECG foundation model for zero-shot transfer from hospital to point-of-care devices

Electrocardiogram (ECG) recording is moving from hospitals to point-of-care devices that record one or two leads, where public labelled data is too scarce to build foundation models (FMs) as for 12-lead ECGs. Whether existing 12-lead FMs transfer to these devices without retraining is unknown. We show that seven published FMs reach a zero-shot AUROC of 41-81% on two real point-of-care datasets and, when reduced to one or two leads, lose 12-35 AUROC points on average and gain 0.15-0.23 in mean absolute error across 29 benchmarks covering 1,673 clinical targets. We present RELAY, a 7-million-parameter FM that represents ECGs as graphs of segments from whichever leads are recorded, without filling missing ones or knowing their identities. Pretrained on 9.2 million 12-lead ECGs, RELAY is competitive with 12 leads, ranks first on both point-of-care datasets (AUROC 87.6% and 81.5%) and on 26 and 22 of 29 benchmarks with one and two random leads, and keeps the most informative operating point when 12-lead thresholds are applied to device recordings. Matched ablations show that omitting absent leads, rather than filling them, reduces what RELAY loses in transfer. ECG FMs should therefore be judged across all the acquisition settings, not on 12-lead benchmarks alone.

查看此版本解读 →查看此版本原文 ↗