跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2609.35203 · v3

NucShare: Lightweight Nuclei Instance Segmentation with Foundation-Model Accuracy

首次提交 2026-09-28 21:59
版本更新 2026-10-29 20:21
雷达观测 2026-10-30 13:28
arXiv ↗PDF ↗

摘要

Nuclei instance segmentation is fundamental to quantitative pathology. Yet high-accuracy methods mostly build on large vision transformers (ViTs) or heavy convolutional backbones, whose parameter count and compute cost hinder deployment in clinical and edge settings. We present NucShare, a lightweight model whose shared decoder handles nuclear pixel segmentation, horizontal-vertical distance, and classification through learnable transposed convolutions for upsampling and three lightweight heads, using 37% of independent decoders' parameters with no loss in accuracy. Output-level distillation then transfers knowledge from NucShare-T (UNI2-h) to NucShare-S (ConvNeXt V2-Tiny), reducing 690.5M parameters to 34.7M. On PanNuke they reach mPQ 0.524 and 0.519, above the prior best CFR-SAM-H at 0.511, and NucShare-S surpasses HoVer-Net and Mask R-CNN by 5.6 and 15.0 points; on zero-shot MoNuSeg it attains bPQ 0.668 against CFR-SAM-H's 0.662. Code: https://github.com/L-iMeng-L/Newidea

作者备注:5 pages, 3 figures, 4 tables. Submitted to IEEE International Symposium on Biomedical Imaging (ISBI 2027)

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v3 · 2026-10-29 20:21 · 最新观测版本

NucShare: Lightweight Nuclei Instance Segmentation with Foundation-Model Accuracy

Nuclei instance segmentation is fundamental to quantitative pathology. Yet high-accuracy methods mostly build on large vision transformers (ViTs) or heavy convolutional backbones, whose parameter count and compute cost hinder deployment in clinical and edge settings. We present NucShare, a lightweight model whose shared decoder handles nuclear pixel segmentation, horizontal-vertical distance, and classification through learnable transposed convolutions for upsampling and three lightweight heads, using 37% of independent decoders' parameters with no loss in accuracy. Output-level distillation then transfers knowledge from NucShare-T (UNI2-h) to NucShare-S (ConvNeXt V2-Tiny), reducing 690.5M parameters to 34.7M. On PanNuke they reach mPQ 0.524 and 0.519, above the prior best CFR-SAM-H at 0.511, and NucShare-S surpasses HoVer-Net and Mask R-CNN by 5.6 and 15.0 points; on zero-shot MoNuSeg it attains bPQ 0.668 against CFR-SAM-H's 0.662. Code: https://github.com/L-iMeng-L/Newidea

查看此版本解读 →查看此版本原文 ↗