← 研踪 PaperTrailarXiv:2610.13056 · v2
A4-MR: Abnormality Aware Anatomical Alignment for MR
首次提交 2026-10-09 14:10
版本更新 2026-10-29 15:52
雷达观测 2026-10-30 13:28
摘要
Recent advances in large-scale foundation models have enabled strong generalization across a wide range of clinical and research tasks in magnetic resonance imaging (MRI). However, existing vision-language MRI models remain limited in anatomy-specific localization and pathology-aware representation, particularly in real-world settings. We introduce A4-MR, a 3D vision-language foundation model trained on approximately 50,000 MRI studies comprising 491,000 series, roughly half of which are paired with radiology reports. A4-MR is designed to: (1) learn anatomy localization through large-scale pretraining with noisy labels; (2) align image and text representations at the anatomical level; and (3) learn distinct representations of healthy and abnormal anatomy. Across a diverse set of downstream tasks, A4-MR outperforms existing foundation models, including a +1.7 AUROC improvement over MedSigLIP for abnormality detection. Using a frozen encoder, A4-MR also surpasses an end-to-end task-specific MedNeXt model for knee segmentation by +1.4 Dice and performs comparably to the best task-specific model for abdominal organ segmentation on AMOS, within 0.4 Dice. Finally, without anatomical prompts, A4-MR localizes 3D anatomy comparably to MedSAM2 provided with ground-truth bounding boxes. Together, these results demonstrate that anatomy-level multimodal alignment and abnormality-aware representation learning can enable a single MRI foundation model to support localization, segmentation, and pathology-related tasks.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v2 · 2026-10-29 15:52 · 最新观测版本
A4-MR: Abnormality Aware Anatomical Alignment for MR
Recent advances in large-scale foundation models have enabled strong generalization across a wide range of clinical and research tasks in magnetic resonance imaging (MRI). However, existing vision-language MRI models remain limited in anatomy-specific localization and pathology-aware representation, particularly in real-world settings. We introduce A4-MR, a 3D vision-language foundation model trained on approximately 50,000 MRI studies comprising 491,000 series, roughly half of which are paired with radiology reports. A4-MR is designed to: (1) learn anatomy localization through large-scale pretraining with noisy labels; (2) align image and text representations at the anatomical level; and (3) learn distinct representations of healthy and abnormal anatomy. Across a diverse set of downstream tasks, A4-MR outperforms existing foundation models, including a +1.7 AUROC improvement over MedSigLIP for abnormality detection. Using a frozen encoder, A4-MR also surpasses an end-to-end task-specific MedNeXt model for knee segmentation by +1.4 Dice and performs comparably to the best task-specific model for abdominal organ segmentation on AMOS, within 0.4 Dice. Finally, without anatomical prompts, A4-MR localizes 3D anatomy comparably to MedSAM2 provided with ground-truth bounding boxes. Together, these results demonstrate that anatomy-level multimodal alignment and abnormality-aware representation learning can enable a single MRI foundation model to support localization, segmentation, and pathology-related tasks.
查看此版本解读 →查看此版本原文 ↗