跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.13357 · v4

ECGGuard: Deep Watermarking of Electrocardiogram Signals With Error-Correcting

首次提交 2026-10-09 18:32
版本更新 2026-11-13 17:28
雷达观测 2026-11-16 11:42
arXiv ↗PDF ↗

摘要

Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, leaving patient metadata vulnerable to loss. Digital watermarking can embed this metadata in the signal, but conventional methods fail under time shifts, and high waveform similarity does not guarantee the same downstream diagnosis. We present \rev{ECGGuard}, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and checks for watermark presence, and during training a frozen arrhythmia classifier penalizes changes that would alter its predictions. Because high bit accuracy does not ensure whole-message recovery, the payload is protected by extended Hamming codes, \rev{a validation-selected channel ordering}, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, \rev{averaged over three training runs, ECGGuard} keeps bit accuracy above \rev{98\%} under time shifts of 10 to 50 samples, where transform-domain baselines drop to chance. The coded 16-bit payload is recovered exactly in \rev{99.95\%} of clean segments\rev{, in over 96\%} under time shifts, 10\% sample deletion, or 10\% packet loss\rev{, and in 99.1\% for unseen subjects}. \rev{For the guiding classifier, the diagnostic loss limits the drop in ventricular-beat sensitivity to 1.6 percentage points on the test records (35.0 without it) and to 12.2 points for unseen subjects (67.0 without it); the drop grows to 10.3 points for independently trained classifiers, and the protection does not transfer to an external database.} \rev{ECGGuard} has 0.56 million parameters and needs about \rev{19}~ms per segment on a desktop CPU.

作者备注:12 pages, 4 figures, 5 tables

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v4,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v4 · 2026-11-13 17:28 · 最新观测版本

ECGGuard: Deep Watermarking of Electrocardiogram Signals With Error-Correcting

Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, leaving patient metadata vulnerable to loss. Digital watermarking can embed this metadata in the signal, but conventional methods fail under time shifts, and high waveform similarity does not guarantee the same downstream diagnosis. We present \rev{ECGGuard}, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and checks for watermark presence, and during training a frozen arrhythmia classifier penalizes changes that would alter its predictions. Because high bit accuracy does not ensure whole-message recovery, the payload is protected by extended Hamming codes, \rev{a validation-selected channel ordering}, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, \rev{averaged over three training runs, ECGGuard} keeps bit accuracy above \rev{98\%} under time shifts of 10 to 50 samples, where transform-domain baselines drop to chance. The coded 16-bit payload is recovered exactly in \rev{99.95\%} of clean segments\rev{, in over 96\%} under time shifts, 10\% sample deletion, or 10\% packet loss\rev{, and in 99.1\% for unseen subjects}. \rev{For the guiding classifier, the diagnostic loss limits the drop in ventricular-beat sensitivity to 1.6 percentage points on the test records (35.0 without it) and to 12.2 points for unseen subjects (67.0 without it); the drop grows to 10.3 points for independently trained classifiers, and the protection does not transfer to an external database.} \rev{ECGGuard} has 0.56 million parameters and needs about \rev{19}~ms per segment on a desktop CPU.

查看此版本解读 →查看此版本原文 ↗