跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.31228 · v2

Lightweight Frame Compensation for Real-Time Polyp Segmentation under Frame Skipping

首次提交 2026-10-22 21:13
版本更新 2026-11-09 20:14
雷达观测 2026-11-10 15:22
arXiv ↗PDF ↗

摘要

Real-time polyp segmentation in computer-assisted colonoscopy is hampered by the difficulty of deploying high-accuracy models under strict latency budgets. Frame skipping, which performs inference every K frames and reuses or interpolates the rest, improves throughput but introduces motion blur and lesion misalignment that degrade temporal consistency. To close this gap, we propose the Lightweight Frame Compensator (LFC), a 77K-parameter plug-and-play module inserted before a frozen segmentation backbone. Operating on a three-frame window, LFC fuses consecutive frames via spatio-temporal attention into a single compensated frame, and is trained only on pseudo-labels generated by a differently seeded model, without any expert annotation. Experiments on three polyp video benchmarks show that LFC recovers most of the accuracy degraded by direct frame skipping and, in several settings, reaches the accuracy of frame-by-frame inference, while retaining a 2.05X--2.55X throughput gain. We further evaluate the temporal stability of three backbones spanning CNN, pyramid Transformer, and global-attention Transformer architectures, revealing a spectrum of sensitivity to frame skipping that arises from how locally or globally each architecture aggregates misaligned input. The compensation gain of LFC follows this spectrum: it is largest for high-capacity Transformer backbones, which achieve the best static accuracy but suffer the most under skip-frame inference. LFC thus offers a lightweight, pluggable, and deployment-friendly route to real-time polyp segmentation.

作者备注:Subsequent analysis revealed a flaw in the evaluation protocol of the proposed lightweight frame compensation. The original experiments did not sufficiently account for highly variable content dynamics, leading to over-optimistic conclusions. The authors are withdrawing this preprint to re-examine the findings under a more rigorous empirical setup.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-09 20:14 · 最新观测版本

Lightweight Frame Compensation for Real-Time Polyp Segmentation under Frame Skipping

Real-time polyp segmentation in computer-assisted colonoscopy is hampered by the difficulty of deploying high-accuracy models under strict latency budgets. Frame skipping, which performs inference every K frames and reuses or interpolates the rest, improves throughput but introduces motion blur and lesion misalignment that degrade temporal consistency. To close this gap, we propose the Lightweight Frame Compensator (LFC), a 77K-parameter plug-and-play module inserted before a frozen segmentation backbone. Operating on a three-frame window, LFC fuses consecutive frames via spatio-temporal attention into a single compensated frame, and is trained only on pseudo-labels generated by a differently seeded model, without any expert annotation. Experiments on three polyp video benchmarks show that LFC recovers most of the accuracy degraded by direct frame skipping and, in several settings, reaches the accuracy of frame-by-frame inference, while retaining a 2.05X--2.55X throughput gain. We further evaluate the temporal stability of three backbones spanning CNN, pyramid Transformer, and global-attention Transformer architectures, revealing a spectrum of sensitivity to frame skipping that arises from how locally or globally each architecture aggregates misaligned input. The compensation gain of LFC follows this spectrum: it is largest for high-capacity Transformer backbones, which achieve the best static accuracy but suffer the most under skip-frame inference. LFC thus offers a lightweight, pluggable, and deployment-friendly route to real-time polyp segmentation.

查看此版本解读 →查看此版本原文 ↗