跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.35311 · v1

Temporal-Difference Calibration of Black-Box Simulators

首次提交 2026-10-26 20:13
版本更新 2026-10-26 20:13
雷达观测 2026-10-29 00:36
arXiv ↗PDF ↗

摘要

We develop a derivative-free temporal-difference (TD) framework for calibrating black-box simulators using one-step transitions from a target system and noisy simulator-generated continuation values. The calibration parameter is defined through Bellman orthogonality, recovering the physical parameter under correct simulator specification and yielding a near-optimal $L_2$ approximation of the policy value under misspecification. We propose three TD algorithms based on random-direction finite differences, distinguished by their query costs and reuse of noisy simulator evaluations. We establish almost-sure convergence, last-iterate mean-square error bounds, and central limit theorems for Polyak-Ruppert averages across four query-noise regimes. Our analysis reveals a specification-dependent bias phenomenon: for two algorithms, the finite-difference bias of the TD estimating equation vanishes at the calibration target under correct specification, even when the gradient surrogate remains biased. This permits a fixed perturbation radius and rate exponents approaching $1/2$ in the simulator rollout budget, whereas misspecification generally recovers the classical Kiefer-Wolfowitz rates. We also develop a few-replicate online bootstrap that yields Student-$t$ calibrated confidence intervals under negligible query noise, and identify a covariance mismatch that can invalidate conventional multiplier inference along Markov trajectories. Finally, a second-stage TD recursion corrects the remaining value discrepancy without additional simulator queries.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-10-26 20:13 · 最新观测版本

Temporal-Difference Calibration of Black-Box Simulators

We develop a derivative-free temporal-difference (TD) framework for calibrating black-box simulators using one-step transitions from a target system and noisy simulator-generated continuation values. The calibration parameter is defined through Bellman orthogonality, recovering the physical parameter under correct simulator specification and yielding a near-optimal $L_2$ approximation of the policy value under misspecification. We propose three TD algorithms based on random-direction finite differences, distinguished by their query costs and reuse of noisy simulator evaluations. We establish almost-sure convergence, last-iterate mean-square error bounds, and central limit theorems for Polyak-Ruppert averages across four query-noise regimes. Our analysis reveals a specification-dependent bias phenomenon: for two algorithms, the finite-difference bias of the TD estimating equation vanishes at the calibration target under correct specification, even when the gradient surrogate remains biased. This permits a fixed perturbation radius and rate exponents approaching $1/2$ in the simulator rollout budget, whereas misspecification generally recovers the classical Kiefer-Wolfowitz rates. We also develop a few-replicate online bootstrap that yields Student-$t$ calibrated confidence intervals under negligible query noise, and identify a covariance mismatch that can invalidate conventional multiplier inference along Markov trajectories. Finally, a second-stage TD recursion corrects the remaining value discrepancy without additional simulator queries.

查看此版本解读 →查看此版本原文 ↗