跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.36852 · v1

When Black-Box Robot Policies Fail: Online Sensor Diagnosis and Repair with a Transparent Surrogate

首次提交 2026-10-27 16:49
版本更新 2026-10-27 16:49
雷达观测 2026-10-29 00:35
arXiv ↗PDF ↗

摘要

Robot foundation models may generalize across tasks and embodiments, but their actions still depend on sensors that can fail. When the policy is frozen or inaccessible, can an external monitor diagnose and repair corrupted inputs without access to its internals? We test a structured surrogate that separates periodic gait from sensor-dependent corrections to guide input repair around a frozen locomotion policy. On simulated Go2, offline diagnosis raises walking success from 259/640 to 429/640 episodes; online repair reaches 382/640, with no triggers in 64 held-out fault-free episodes. A matched boosted-tree surrogate predicts clean actions similarly well but yields no detected repair improvement over no repair. Separate fits improve walking on Go1 and ANYmal C, although phase-aware gradients perform better. Evidence remains limited to one policy and a partly screened simulated fault suite; robot foundation model and hardware validation remain open.

作者备注:Accepted at the Conference on Robot Learning 2026 Workshop on the Science of Physical AI Safety (SPAIS)

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-10-27 16:49 · 最新观测版本

When Black-Box Robot Policies Fail: Online Sensor Diagnosis and Repair with a Transparent Surrogate

Robot foundation models may generalize across tasks and embodiments, but their actions still depend on sensors that can fail. When the policy is frozen or inaccessible, can an external monitor diagnose and repair corrupted inputs without access to its internals? We test a structured surrogate that separates periodic gait from sensor-dependent corrections to guide input repair around a frozen locomotion policy. On simulated Go2, offline diagnosis raises walking success from 259/640 to 429/640 episodes; online repair reaches 382/640, with no triggers in 64 held-out fault-free episodes. A matched boosted-tree surrogate predicts clean actions similarly well but yields no detected repair improvement over no repair. Separate fits improve walking on Go1 and ANYmal C, although phase-aware gradients perform better. Evidence remains limited to one policy and a partly screened simulated fault suite; robot foundation model and hardware validation remain open.

查看此版本解读 →查看此版本原文 ↗