跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.37350 · v1

Generalizable Target-Less Joint Intrinsic-Extrinsic Camera-LiDAR Calibration using Deep Pixel-Point Correspondences

首次提交 2026-10-27 22:51
版本更新 2026-10-27 22:51
雷达观测 2026-10-29 00:34
arXiv ↗PDF ↗

摘要

Accurate camera-LiDAR calibration is an essential prerequisite for robust multi-modal perception in robotics. Recent target-less methods based on learned pixel-point correspondences achieve high extrinsic calibration accuracy and generalize across environments. However, they operate on rectified images with known camera intrinsics, restricting their applicability to systems whose cameras have already been individually calibrated. We present a fully automatic, target-less framework that jointly estimates camera intrinsics, radial-tangential distortion, and camera-LiDAR extrinsics from raw images and LiDAR scans. Our method generalizes deep correspondence-based calibration from rectified images to raw cameras through intrinsic- and distortion-aware correspondence learning via synthetic augmentations. During calibration, we iteratively couple correspondence prediction and nonlinear optimization to jointly refine the camera parameters and relative sensor transformation. We evaluate our approach on an unseen camera-LiDAR configuration from the KITTI dataset and on three real robotic platforms in a zero-shot manner. The results demonstrate that joint calibration with our generalized pixel-point correspondence network improves extrinsic accuracy over correspondence-based methods using pre-calibrated cameras, while additionally recovering accurate intrinsics.

作者备注:8 pages, 5 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-10-27 22:51 · 最新观测版本

Generalizable Target-Less Joint Intrinsic-Extrinsic Camera-LiDAR Calibration using Deep Pixel-Point Correspondences

Accurate camera-LiDAR calibration is an essential prerequisite for robust multi-modal perception in robotics. Recent target-less methods based on learned pixel-point correspondences achieve high extrinsic calibration accuracy and generalize across environments. However, they operate on rectified images with known camera intrinsics, restricting their applicability to systems whose cameras have already been individually calibrated. We present a fully automatic, target-less framework that jointly estimates camera intrinsics, radial-tangential distortion, and camera-LiDAR extrinsics from raw images and LiDAR scans. Our method generalizes deep correspondence-based calibration from rectified images to raw cameras through intrinsic- and distortion-aware correspondence learning via synthetic augmentations. During calibration, we iteratively couple correspondence prediction and nonlinear optimization to jointly refine the camera parameters and relative sensor transformation. We evaluate our approach on an unseen camera-LiDAR configuration from the KITTI dataset and on three real robotic platforms in a zero-shot manner. The results demonstrate that joint calibration with our generalized pixel-point correspondence network improves extrinsic accuracy over correspondence-based methods using pre-calibrated cameras, while additionally recovering accurate intrinsics.

查看此版本解读 →查看此版本原文 ↗