跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.38786 · v1

Adversarial Process Disturbances at a Deployable Alarm Budget: Detector Evaluation on a Simulator and a Real Plant

首次提交 2026-10-29 03:56
版本更新 2026-10-29 03:56
雷达观测 2026-10-30 10:22
arXiv ↗PDF ↗

摘要

Industrial anomaly detection is evaluated largely on simulators, and recent work reports large drops, with unstable rankings, on real plant data. We ask whether that extends to the security case. We evaluate eleven detectors across classical, neural, dependency and causal families on a simulated chemical process and a sodium thermal-hydraulic facility: different processes sharing no equipment, but both continuous, at steady state, and perturbed only through temperature, pressure, flow and valve, never composition. Three conditions prior work does not cover: disturbances authored against a threat model rather than native faults; one construction applied to both processes; and detection read at a declared false-alarm budget. The drop persists throughout. The simulator panel looks deployable, neural matching classical; on plant telemetry detection collapses and the neural family trails, a gap that in-sample thresholds likely understate. Which detector wins transfers between the two processes; how often it fires does not. Two results hold on both. Sequential valve manipulation defeats the whole panel: at tier 2 no detector flags more than 0.17 of its perturbed samples, against 0.89 or better for most disturbances. And the plant's collapse is not merely that its disturbances are weaker, though they are by about twelvefold; matched on measured strength, the plant is never the better detected.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-10-29 03:56 · 最新观测版本

Adversarial Process Disturbances at a Deployable Alarm Budget: Detector Evaluation on a Simulator and a Real Plant

Industrial anomaly detection is evaluated largely on simulators, and recent work reports large drops, with unstable rankings, on real plant data. We ask whether that extends to the security case. We evaluate eleven detectors across classical, neural, dependency and causal families on a simulated chemical process and a sodium thermal-hydraulic facility: different processes sharing no equipment, but both continuous, at steady state, and perturbed only through temperature, pressure, flow and valve, never composition. Three conditions prior work does not cover: disturbances authored against a threat model rather than native faults; one construction applied to both processes; and detection read at a declared false-alarm budget. The drop persists throughout. The simulator panel looks deployable, neural matching classical; on plant telemetry detection collapses and the neural family trails, a gap that in-sample thresholds likely understate. Which detector wins transfers between the two processes; how often it fires does not. Two results hold on both. Sequential valve manipulation defeats the whole panel: at tier 2 no detector flags more than 0.17 of its perturbed samples, against 0.89 or better for most disturbances. And the plant's collapse is not merely that its disturbances are weaker, though they are by about twelvefold; matched on measured strength, the plant is never the better detected.

查看此版本解读 →查看此版本原文 ↗