← 研踪 PaperTrailarXiv:2611.00920 · v2
Non-intrusive appliance state detection in unseen homes using classical machine learning
首次提交 2026-10-31 21:22
版本更新 2026-11-08 21:53
雷达观测 2026-11-10 12:16
摘要
Non-intrusive load monitoring (NILM) infers, from the aggregate signal of a single smart meter, when each appliance in a home is ON or OFF, offering significant potential to enhance energy efficiency. Classical machine-learning detectors report F1 scores (the harmonic mean of precision and recall) from 0.53 to 0.98, but the causes of this spread are unseparated, so it is unclear which design choices matter. Real-world deployments, however, require detectors that work in houses never seen during training, whereas most studies test on houses used for training. To address this challenge, we propose a factorial analysis of variance design that separates the effects of classifier, feature set and class-imbalance strategy across five appliances (270 configurations), and a leave-house-out protocol with house-grouped model selection. Unlike studies that vary one factor at a time or pool houses, the approach attributes performance to each factor and measures it on unseen homes. Extensive experiments on REFIT, a public dataset of 20 UK households, show that the appliance explains 38 percent of F1 variance, the feature set 13 percent, the classifier 8 percent and the imbalance strategy 2 percent. Pooled testing overstates support-weighted F1 (0.548 versus 0.447 in unseen houses), class weighting gains grow from 32 percent to 69 percent, and feature engineering gives the same 52 percent gain in both protocols. House-grouped selection raises F1 for three of five appliances, by up to 0.110, and a convolutional neural network scores 0.450 (0.496 calibrated) against 0.447 for classical models. The findings guide appliance-level monitoring in smart-metering and energy-management systems.
作者备注:49 pages, 9 figures
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v2 · 2026-11-08 21:53 · 最新观测版本
Non-intrusive appliance state detection in unseen homes using classical machine learning
Non-intrusive load monitoring (NILM) infers, from the aggregate signal of a single smart meter, when each appliance in a home is ON or OFF, offering significant potential to enhance energy efficiency. Classical machine-learning detectors report F1 scores (the harmonic mean of precision and recall) from 0.53 to 0.98, but the causes of this spread are unseparated, so it is unclear which design choices matter. Real-world deployments, however, require detectors that work in houses never seen during training, whereas most studies test on houses used for training. To address this challenge, we propose a factorial analysis of variance design that separates the effects of classifier, feature set and class-imbalance strategy across five appliances (270 configurations), and a leave-house-out protocol with house-grouped model selection. Unlike studies that vary one factor at a time or pool houses, the approach attributes performance to each factor and measures it on unseen homes. Extensive experiments on REFIT, a public dataset of 20 UK households, show that the appliance explains 38 percent of F1 variance, the feature set 13 percent, the classifier 8 percent and the imbalance strategy 2 percent. Pooled testing overstates support-weighted F1 (0.548 versus 0.447 in unseen houses), class weighting gains grow from 32 percent to 69 percent, and feature engineering gives the same 52 percent gain in both protocols. House-grouped selection raises F1 for three of five appliances, by up to 0.110, and a convolutional neural network scores 0.450 (0.496 calibrated) against 0.447 for classical models. The findings guide appliance-level monitoring in smart-metering and energy-management systems.
查看此版本解读 →查看此版本原文 ↗