跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.01222 · v1

Modeling Fat-shift for Improved Head Segmentation from MRI Scans using a Probabilistic Model

首次提交 2026-11-01 03:44
版本更新 2026-11-01 03:44
雷达观测 2026-11-04 23:43
arXiv ↗PDF ↗

摘要

Personalized computational head models for biophysical simulations rely on accurate whole-head segmentations from T1-weighted (T1w) magnetic resonance imaging (MRI) scans. While T1w scans provide excellent contrast for intracranial anatomy, extracerebral tissues have partly almost no signal (compact bone) and also suffer from the so-called chemical shift artifact, which affects the fatty tissues in MRI and causes them to spatially shift in the frequency encoding direction of the scan. This artifact occurs primarily in two structures of the head: the spongy bone, a fatty compartment inside the compact bone, and the subcutaneous fat, located directly underneath the skin. The frequency-encoding direction is often set in the superior-inferior direction, causing the fatty tissues to shift down and, as a result, making the skull appear thinner than it actually is. Existing segmentation methods do not model this artifact, consequently leading to inaccurate labeling of the skull and scalp, which introduces a bias in biophysical simulations. The direction and magnitude of the fat-shift can be determined from the scan parameters, thus making it possible to explicitly model the shift and to recover the correct anatomy. This study introduces a probabilistic model that uses variational inference to segment head and brain structures from a T1w scan while accounting for the fat-shift artifact. The proposed Fat-shift-informed Label Optimization of the Whole head (FLOW) method reconstructs extracerebral anatomy more accurately than a fat-shift-agnostic segmentation approach while maintaining high segmentation accuracy in all other structures. FLOW-based fat-shift corrected segmentations significantly reduce bias in electric field simulations compared to a segmentation method that does not model the shift.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-01 03:44 · 最新观测版本

Modeling Fat-shift for Improved Head Segmentation from MRI Scans using a Probabilistic Model

Personalized computational head models for biophysical simulations rely on accurate whole-head segmentations from T1-weighted (T1w) magnetic resonance imaging (MRI) scans. While T1w scans provide excellent contrast for intracranial anatomy, extracerebral tissues have partly almost no signal (compact bone) and also suffer from the so-called chemical shift artifact, which affects the fatty tissues in MRI and causes them to spatially shift in the frequency encoding direction of the scan. This artifact occurs primarily in two structures of the head: the spongy bone, a fatty compartment inside the compact bone, and the subcutaneous fat, located directly underneath the skin. The frequency-encoding direction is often set in the superior-inferior direction, causing the fatty tissues to shift down and, as a result, making the skull appear thinner than it actually is. Existing segmentation methods do not model this artifact, consequently leading to inaccurate labeling of the skull and scalp, which introduces a bias in biophysical simulations. The direction and magnitude of the fat-shift can be determined from the scan parameters, thus making it possible to explicitly model the shift and to recover the correct anatomy. This study introduces a probabilistic model that uses variational inference to segment head and brain structures from a T1w scan while accounting for the fat-shift artifact. The proposed Fat-shift-informed Label Optimization of the Whole head (FLOW) method reconstructs extracerebral anatomy more accurately than a fat-shift-agnostic segmentation approach while maintaining high segmentation accuracy in all other structures. FLOW-based fat-shift corrected segmentations significantly reduce bias in electric field simulations compared to a segmentation method that does not model the shift.

查看此版本解读 →查看此版本原文 ↗