跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.05618 · v1

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

首次提交 2026-11-04 05:02
版本更新 2026-11-04 05:02
雷达观测 2026-11-05 10:08
arXiv ↗PDF ↗

摘要

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-04 05:02 · 最新观测版本

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

查看此版本解读 →查看此版本原文 ↗