跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.05693 · v1

Anchored Slice Propagation with Boundary Transport for 3D CT Segmentation from Three Orthogonal Annotated Slices

首次提交 2026-11-04 06:21
版本更新 2026-11-04 06:21
雷达观测 2026-11-05 10:08
arXiv ↗PDF ↗

摘要

Sli2Vol propagates a binary mask through affinities between adjacent slices, but an error can persist because each prediction becomes the input to the next step. Three orthogonal annotations reduce dependence on any one chain, yet they offer more than three starting masks: where a chain crosses another annotated plane, the correct label is already known. Those labels could correct drift during propagation and indicate how much to trust each chain at fusion. Between annotated planes, the information carried by the chain may matter as well. A binary mask records foreground membership but discards distance to the boundary, a cue that could help follow gradual shape changes between slices.We address these two sources of error with a fixed pretrained affinity backbone. We anchor each chain by correcting its prediction where it crosses another annotated plane, then use its agreement with those labels to weight fusion. We compare this anchored mask with two ways of transporting boundary geometry: a truncated signed-distance field (SDF) propagated by dense affinity averaging, and a contour whose vertices follow motion cues from the same affinity. The contour tracker starts from a hand-crafted rule and learns a motion correction from supervoxel pseudo-objects in 506 CT volumes, without manual organ labels. On 2,091 held-out structure instances from approximately 403 CT scans spanning 17 abdominal structures, anchoring raises mean Dice from 0.737 with orthogonal mask propagation to 0.769 and improves every structure. Beyond the anchored mask, learned contour tracking improves Dice by 5.7\% for the esophagus and 5.9\% for the postcava, while SDF transport improves right-adrenal Dice by 2.8\%. The anchored methods have similar mean Dice (0.769--0.772); contour tracking performs worse on the kidneys, stomach, and hepatic vessel tree.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-04 06:21 · 最新观测版本

Anchored Slice Propagation with Boundary Transport for 3D CT Segmentation from Three Orthogonal Annotated Slices

Sli2Vol propagates a binary mask through affinities between adjacent slices, but an error can persist because each prediction becomes the input to the next step. Three orthogonal annotations reduce dependence on any one chain, yet they offer more than three starting masks: where a chain crosses another annotated plane, the correct label is already known. Those labels could correct drift during propagation and indicate how much to trust each chain at fusion. Between annotated planes, the information carried by the chain may matter as well. A binary mask records foreground membership but discards distance to the boundary, a cue that could help follow gradual shape changes between slices.We address these two sources of error with a fixed pretrained affinity backbone. We anchor each chain by correcting its prediction where it crosses another annotated plane, then use its agreement with those labels to weight fusion. We compare this anchored mask with two ways of transporting boundary geometry: a truncated signed-distance field (SDF) propagated by dense affinity averaging, and a contour whose vertices follow motion cues from the same affinity. The contour tracker starts from a hand-crafted rule and learns a motion correction from supervoxel pseudo-objects in 506 CT volumes, without manual organ labels. On 2,091 held-out structure instances from approximately 403 CT scans spanning 17 abdominal structures, anchoring raises mean Dice from 0.737 with orthogonal mask propagation to 0.769 and improves every structure. Beyond the anchored mask, learned contour tracking improves Dice by 5.7\% for the esophagus and 5.9\% for the postcava, while SDF transport improves right-adrenal Dice by 2.8\%. The anchored methods have similar mean Dice (0.769--0.772); contour tracking performs worse on the kidneys, stomach, and hepatic vessel tree.

查看此版本解读 →查看此版本原文 ↗