跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.06540 · v1

Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion

首次提交 2026-11-04 22:10
版本更新 2026-11-04 22:10
雷达观测 2026-11-05 12:13
arXiv ↗PDF ↗

摘要

Glioblastoma exhibits substantial heterogeneity in tumour morphology and composition across MRI modalities, often making available clinical datasets highly unbalanced in terms of patient pathologies. We propose a two-stage latent diffusion model (LDM) framework for the generation of explicitly controllable 2D glioblastoma MRI scans. First, a segmentation LDM generates tumour maps conditioned on location, spatial extent, axial position, and subregion composition. Second, a modality-conditioned LDM with ControlNet generates T1, T1Gd, T2, and FLAIR images adhering to the requested segmentation. On a held-out test set, generated segmentations achieved a mean centroid error of 0.842 pixels and a subregion proportion error of 0.795 percentage points. ControlNet improved Fréchet inception distance (FID) across all four modalities, reducing pooled FID from 42.59 to 36.12. An expert reader study yielded mean quality ratings of 6.60 for real images, 6.83 for ControlNet-generated images, and 6.77 for fully synthetic images.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-04 22:10 · 最新观测版本

Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion

Glioblastoma exhibits substantial heterogeneity in tumour morphology and composition across MRI modalities, often making available clinical datasets highly unbalanced in terms of patient pathologies. We propose a two-stage latent diffusion model (LDM) framework for the generation of explicitly controllable 2D glioblastoma MRI scans. First, a segmentation LDM generates tumour maps conditioned on location, spatial extent, axial position, and subregion composition. Second, a modality-conditioned LDM with ControlNet generates T1, T1Gd, T2, and FLAIR images adhering to the requested segmentation. On a held-out test set, generated segmentations achieved a mean centroid error of 0.842 pixels and a subregion proportion error of 0.795 percentage points. ControlNet improved Fréchet inception distance (FID) across all four modalities, reducing pooled FID from 42.59 to 36.12. An expert reader study yielded mean quality ratings of 6.60 for real images, 6.83 for ControlNet-generated images, and 6.77 for fully synthetic images.

查看此版本解读 →查看此版本原文 ↗