Visible cameras fail at night and thermal sensors fail under saturation, blur or loss of contrast, yet most RGB-thermal (RGB-T) detectors mix the two streams with fixed weights and cannot tell when one modality has become unreliable. TriNetra is a reliability-aware surveillance framework built around this problem. The proposed solution computes a frame-level Thermal Reliability Coefficient (TRC) from five label-free image cues, uses it to gate the thermal features of a dual-branch YOLOv8m detector whose visible branch, neck and head are frozen and COCO-pretrained, and passes the same score to a ByteTrack-based tracker that feeds a rule-based behaviour analyser. On the M3FD benchmark (2,940/630/630 split) the detector reaches 87.6% precision, 79.4% recall, 70.0% mAP@50 and 47.8% mAP@50:95 on the test split, with 17.0 M of its 42.9 M parameters trained. TRC stays near 0.78 on clean frames (standard deviation 0.012), decreases with the severity of thermal saturation and blur, reaching 0.53 and 0.69 at full severity, and is insensitive to RGB-thermal misalignment. With identical weights, the adaptive gate matches a fixed gate on clean data (70.0% versus 69.8% mAP@50) but keeps 43.6% mAP@50 when the thermal stream is corrupted, against 38.4%, 29.2% and 25.0% for a fixed gate, full thermal admission and a closed gate; the 5.1-point gain over the fixed gate has a 95% bootstrap confidence interval of +3.6 to +6.5 points. In tracking, the TRC-gated association performs on par with ByteTrack on a synthetic benchmark with exact ground truth and on 14 M3FD clips, and is slightly less stable under thermal saturation, so its measured benefit is confined to the detector. The limitations of the current evaluation are reported together with the results.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-07 01:01 · 最新观测版本

TriNetra: Thermal-Reliability-Guided RGB-Thermal Fusion and Tracking for Surveillance

Visible cameras fail at night and thermal sensors fail under saturation, blur or loss of contrast, yet most RGB-thermal (RGB-T) detectors mix the two streams with fixed weights and cannot tell when one modality has become unreliable. TriNetra is a reliability-aware surveillance framework built around this problem. The proposed solution computes a frame-level Thermal Reliability Coefficient (TRC) from five label-free image cues, uses it to gate the thermal features of a dual-branch YOLOv8m detector whose visible branch, neck and head are frozen and COCO-pretrained, and passes the same score to a ByteTrack-based tracker that feeds a rule-based behaviour analyser. On the M3FD benchmark (2,940/630/630 split) the detector reaches 87.6% precision, 79.4% recall, 70.0% mAP@50 and 47.8% mAP@50:95 on the test split, with 17.0 M of its 42.9 M parameters trained. TRC stays near 0.78 on clean frames (standard deviation 0.012), decreases with the severity of thermal saturation and blur, reaching 0.53 and 0.69 at full severity, and is insensitive to RGB-thermal misalignment. With identical weights, the adaptive gate matches a fixed gate on clean data (70.0% versus 69.8% mAP@50) but keeps 43.6% mAP@50 when the thermal stream is corrupted, against 38.4%, 29.2% and 25.0% for a fixed gate, full thermal admission and a closed gate; the 5.1-point gain over the fixed gate has a 95% bootstrap confidence interval of +3.6 to +6.5 points. In tracking, the TRC-gated association performs on par with ByteTrack on a synthetic benchmark with exact ground truth and on 14 M3FD clips, and is slightly less stable under thermal saturation, so its measured benefit is confined to the detector. The limitations of the current evaluation are reported together with the results.

查看此版本解读 →查看此版本原文 ↗