← 研踪 PaperTrailarXiv:2611.11258 · v1
Auto-GlaKG: Automated Biomarker Reasoning for Explainable Glaucoma Detection
首次提交 2026-11-08 17:21
版本更新 2026-11-08 17:21
雷达观测 2026-11-10 12:16
摘要
Interpretable glaucoma detection requires a transparent connection between fundus images, clinically meaningful biomarkers, and diagnostic predictions. Knowledge graph (KG) reasoning provides this structure, but performance measured using annotated biomarkers does not establish performance when only images are available. We present Auto-GlaKG, an automated framework that combines image-based biomarker prediction with fixed clinical-prior rules. A ResNet50 network predicts the cup-to-disc ratio (CDR) and six morphological signs using biomarker supervision, and a KG reasoner aggregates their signed rule contributions into a glaucoma score. On 689 fundus images evaluated using stratified, group-aware five-fold cross-validation, Auto-GlaKG achieves a pooled area under the receiver operating characteristic curve (AUC) of 0.951 (95\% confidence interval: 0.931--0.969), with sensitivity of 0.970 and specificity of 0.779. The matched image classifier also achieves an AUC of 0.951, while the rule stage adds 0.2~ms per image. Replacing predicted CDR with its annotation increases fold-mean AUC from 0.953 to 0.995. The framework provides an explicit rule-level account of image-based predictions and identifies CDR estimation as a priority for validation using independently measured biomarkers.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-08 17:21 · 最新观测版本
Auto-GlaKG: Automated Biomarker Reasoning for Explainable Glaucoma Detection
Interpretable glaucoma detection requires a transparent connection between fundus images, clinically meaningful biomarkers, and diagnostic predictions. Knowledge graph (KG) reasoning provides this structure, but performance measured using annotated biomarkers does not establish performance when only images are available. We present Auto-GlaKG, an automated framework that combines image-based biomarker prediction with fixed clinical-prior rules. A ResNet50 network predicts the cup-to-disc ratio (CDR) and six morphological signs using biomarker supervision, and a KG reasoner aggregates their signed rule contributions into a glaucoma score. On 689 fundus images evaluated using stratified, group-aware five-fold cross-validation, Auto-GlaKG achieves a pooled area under the receiver operating characteristic curve (AUC) of 0.951 (95\% confidence interval: 0.931--0.969), with sensitivity of 0.970 and specificity of 0.779. The matched image classifier also achieves an AUC of 0.951, while the rule stage adds 0.2~ms per image. Replacing predicted CDR with its annotation increases fold-mean AUC from 0.953 to 0.995. The framework provides an explicit rule-level account of image-based predictions and identifies CDR estimation as a priority for validation using independently measured biomarkers.
查看此版本解读 →查看此版本原文 ↗