跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.12026 · v1

MambaPD: Bidirectional Selective State Space Model for Parkinson's Disease Detection from Resting-State EEG

首次提交 2026-11-09 16:03
版本更新 2026-11-09 16:03
雷达观测 2026-11-10 13:18
arXiv ↗PDF ↗

摘要

Typical diagnosis of Parkinson's disease (PD) occurs only after significant dopaminergic loss, while resting-state EEG abnormalities like alpha slowing and reduced coherence occur earlier. While many published EEG-based PD detectors claim accuracy greater than 95%, many use epoch-level splits which leak subject identity. I introduce MambaPD, a bidirectional selective state space model for resting-state EEG-based PD detection, blending the channel mixing, patch tokenization and bidirectional Mamba encoder. It is compared with four baselines (TCN, BiLSTM with attention, EEGNet and a patch Transformer) in two public datasets (UNM, SanDiego) using subject-independent 5-fold cross-validation (checkpoints were selected on the held-out fold, so absolute estimates are optimistic). On UNM the accuracy is between 0.67 and 0.71, and MambaPD (0.714) is not statistically distinguishable from the Transformer (0.715), and TCN (0.708), with the highest sensitivity (0.82), while the lowest specificity (0.52). For the smaller SanDiego cohort, accuracy is in the range of 0.60 to 0.70, with the highest scores (0.703) from TCN and the lowest (0.601) from EEGNet, while MambaPD scores 0.631, with the lowest specificity (0.46) among the five models. The differences among the models on UNM are minor compared to the differences among folds. I report the whole pipeline, per-fold results, and the shortcomings of the protocol.

作者备注:17 pages, 11 figures, 9 tables

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-09 16:03 · 最新观测版本

MambaPD: Bidirectional Selective State Space Model for Parkinson's Disease Detection from Resting-State EEG

Typical diagnosis of Parkinson's disease (PD) occurs only after significant dopaminergic loss, while resting-state EEG abnormalities like alpha slowing and reduced coherence occur earlier. While many published EEG-based PD detectors claim accuracy greater than 95%, many use epoch-level splits which leak subject identity. I introduce MambaPD, a bidirectional selective state space model for resting-state EEG-based PD detection, blending the channel mixing, patch tokenization and bidirectional Mamba encoder. It is compared with four baselines (TCN, BiLSTM with attention, EEGNet and a patch Transformer) in two public datasets (UNM, SanDiego) using subject-independent 5-fold cross-validation (checkpoints were selected on the held-out fold, so absolute estimates are optimistic). On UNM the accuracy is between 0.67 and 0.71, and MambaPD (0.714) is not statistically distinguishable from the Transformer (0.715), and TCN (0.708), with the highest sensitivity (0.82), while the lowest specificity (0.52). For the smaller SanDiego cohort, accuracy is in the range of 0.60 to 0.70, with the highest scores (0.703) from TCN and the lowest (0.601) from EEGNet, while MambaPD scores 0.631, with the lowest specificity (0.46) among the five models. The differences among the models on UNM are minor compared to the differences among folds. I report the whole pipeline, per-fold results, and the shortcomings of the protocol.

查看此版本解读 →查看此版本原文 ↗