跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.12695 · v1

TACTUS: A Robotic Palpation System for Spatially Heterogeneous Hardness Mapping of Woody Breast Myopathy

首次提交 2026-11-10 00:55
版本更新 2026-11-10 00:55
雷达观测 2026-11-10 15:22
arXiv ↗PDF ↗

摘要

Woody breast (WB) myopathy is a spatially heterogeneous fibro-degenerative condition of the broiler Pectoralis major muscle. Existing mechanical reference methods rely on single-point or sequential compression measurements, limiting characterization of spatial hardness variability. This study presents TACTUS (Tactile Adaptive Conformal 3D Uniform Sensing), an automated tactile array that generates thickness-normalized, three-dimensional hardness maps at 20 anatomically distributed locations within approximately 30 s. TACTUS integrates 20 independently motorized tactuators with force-sensing resistors and encoder-driven linear actuators, alongside a LiDAR depth camera for surface profiling and adaptive compression. The system was evaluated using 100 broiler breast fillets across four WB severity classes (Normal, Mild, Moderate, Severe). TACTUS identified significant force differences among severity classes (ANOVA, p < 0.001), with the strongest differentiation in the cranial region and a significant caudal effect not detected by texture-analyzer measurements. Fillet-level TACTUS force showed moderate but significant correlation with texture-analyzer measurements (Pearson r = 0.441, p < 0.001). Semivariogram, local change entropy, and heterogeneity analyses revealed increasing and anatomically structured hardness variability with WB severity. These findings demonstrate TACTUS as an automated, operator-independent platform for spatially resolved mechanical characterization and ground-truth generation to support hyperspectral and near-infrared spectroscopy-based WB classification systems.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-10 00:55 · 最新观测版本

TACTUS: A Robotic Palpation System for Spatially Heterogeneous Hardness Mapping of Woody Breast Myopathy

Woody breast (WB) myopathy is a spatially heterogeneous fibro-degenerative condition of the broiler Pectoralis major muscle. Existing mechanical reference methods rely on single-point or sequential compression measurements, limiting characterization of spatial hardness variability. This study presents TACTUS (Tactile Adaptive Conformal 3D Uniform Sensing), an automated tactile array that generates thickness-normalized, three-dimensional hardness maps at 20 anatomically distributed locations within approximately 30 s. TACTUS integrates 20 independently motorized tactuators with force-sensing resistors and encoder-driven linear actuators, alongside a LiDAR depth camera for surface profiling and adaptive compression. The system was evaluated using 100 broiler breast fillets across four WB severity classes (Normal, Mild, Moderate, Severe). TACTUS identified significant force differences among severity classes (ANOVA, p < 0.001), with the strongest differentiation in the cranial region and a significant caudal effect not detected by texture-analyzer measurements. Fillet-level TACTUS force showed moderate but significant correlation with texture-analyzer measurements (Pearson r = 0.441, p < 0.001). Semivariogram, local change entropy, and heterogeneity analyses revealed increasing and anatomically structured hardness variability with WB severity. These findings demonstrate TACTUS as an automated, operator-independent platform for spatially resolved mechanical characterization and ground-truth generation to support hyperspectral and near-infrared spectroscopy-based WB classification systems.

查看此版本解读 →查看此版本原文 ↗