跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.14425 · v1

Quantifying the Sampling Frequency Invariance of Time-Series Foundation Models for Sensor Data Applications

首次提交 2026-11-11 02:01
版本更新 2026-11-11 02:01
雷达观测 2026-11-11 13:07
arXiv ↗PDF ↗

摘要

Time-Series Foundation Models (TSFMs) are increasingly used in sensor applications, where sampling frequency (SF) varies across sensors, devices, and operating modes (e.g., power saving). Ideally, TSFMs must remain effective during such SF changes, provided the SF retains task-critical bandwidth. In this paper, we stress-test 4 prominent TSFMs: MOMENT, Chronos-2, Moirai-MoE, and TimesFM, to quantify their SF-invariance and investigate whether their behavior tracks the resulting loss of information bandwidth rather than the SF value itself. Our stress-test probes 3 dimensions: (i) the shift in embeddings, (ii) the degradation in forecasting performance, and (iii) the degradation in downstream performance, quantified by three novel metrics: FSI, FDI, and CDI, respectively. To our knowledge, this is the first study to place SF-invariance at the core of TSFM evaluations. Our results characterize: (i) how SF-invariance depends on the margin between signal's native-SF and the bandwidth its task requires, (ii) how much of that invariance the choice of TSFM explains, and (iii) how much of TSFM's performance degradation under a lower SF reflects information loss rather than a limitation of their abilities. These findings reframe SF-invariance as a measurable, signal-aware property of the (signal X TSFM) pair, and guide practitioners on when TSFMs display SF-invariance.

AI 论文解读

基于摘要 · 非全文审阅

该研究对四个主流时间序列基础模型进行压力测试,量化其在采样频率变化下的不变性,并考察性能退化是否与信息带宽损失相关。

正在读取账号与研究记录…

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-11 02:01 · 最新观测版本

Quantifying the Sampling Frequency Invariance of Time-Series Foundation Models for Sensor Data Applications

Time-Series Foundation Models (TSFMs) are increasingly used in sensor applications, where sampling frequency (SF) varies across sensors, devices, and operating modes (e.g., power saving). Ideally, TSFMs must remain effective during such SF changes, provided the SF retains task-critical bandwidth. In this paper, we stress-test 4 prominent TSFMs: MOMENT, Chronos-2, Moirai-MoE, and TimesFM, to quantify their SF-invariance and investigate whether their behavior tracks the resulting loss of information bandwidth rather than the SF value itself. Our stress-test probes 3 dimensions: (i) the shift in embeddings, (ii) the degradation in forecasting performance, and (iii) the degradation in downstream performance, quantified by three novel metrics: FSI, FDI, and CDI, respectively. To our knowledge, this is the first study to place SF-invariance at the core of TSFM evaluations. Our results characterize: (i) how SF-invariance depends on the margin between signal's native-SF and the bandwidth its task requires, (ii) how much of that invariance the choice of TSFM explains, and (iii) how much of TSFM's performance degradation under a lower SF reflects information loss rather than a limitation of their abilities. These findings reframe SF-invariance as a measurable, signal-aware property of the (signal X TSFM) pair, and guide practitioners on when TSFMs display SF-invariance.

查看此版本解读 →查看此版本原文 ↗