Supervision-Aware Evaluation of MedGemma for Reference-Assisted Radiotherapy Contour Ranking

首次提交 2026-11-11 19:50
版本更新 2026-11-11 19:50
雷达观测 2026-11-13 11:11
arXiv ↗PDF ↗

摘要

Radiotherapy contour ranking can support quality assurance, but vision-language model (VLM) gains may reflect supervision, score construction, available inputs, or representation access. We evaluated frozen MedGemma 1.5 in a single-institution study, a 12-patient held-out HaN-Seg test, five-fold cross-fitting on 30 non-test HaN-Seg patients, and transfer without refitting to 120 SegRap2023 patients. On held-out HaN-Seg, a supervised readout of the final prompt state exceeded a supervised readout of the model's yes/no output probabilities by +0.3047 pooled average precision (AP; 95% patient-bootstrap interval [+0.2822, +0.3269]); the advantage persisted against a parameter-count-matched nonlinear control. A readout of projected visual tokens exceeded the final-state readout in cross-fitting and transfer (+0.0706 AP averaged equally across patients on SegRap; 95% interval [+0.0607, +0.0804]), while a structured panel-feature readout remained competitive with visual tokens. The anatomy-conditioned readout did not demonstrate an advantage over the native-feature comparator. These results motivate visual-token and structured-feature controls in medical-imaging VLM evaluations; outcomes were computational or synthetic, not clinical acceptability.

作者备注:5 pages, 1 figure, 3 tables. Submitted to IEEE ISBI 2027

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-11 19:50 · 最新观测版本

Supervision-Aware Evaluation of MedGemma for Reference-Assisted Radiotherapy Contour Ranking

Radiotherapy contour ranking can support quality assurance, but vision-language model (VLM) gains may reflect supervision, score construction, available inputs, or representation access. We evaluated frozen MedGemma 1.5 in a single-institution study, a 12-patient held-out HaN-Seg test, five-fold cross-fitting on 30 non-test HaN-Seg patients, and transfer without refitting to 120 SegRap2023 patients. On held-out HaN-Seg, a supervised readout of the final prompt state exceeded a supervised readout of the model's yes/no output probabilities by +0.3047 pooled average precision (AP; 95% patient-bootstrap interval [+0.2822, +0.3269]); the advantage persisted against a parameter-count-matched nonlinear control. A readout of projected visual tokens exceeded the final-state readout in cross-fitting and transfer (+0.0706 AP averaged equally across patients on SegRap; 95% interval [+0.0607, +0.0804]), while a structured panel-feature readout remained competitive with visual tokens. The anatomy-conditioned readout did not demonstrate an advantage over the native-feature comparator. These results motivate visual-token and structured-feature controls in medical-imaging VLM evaluations; outcomes were computational or synthetic, not clinical acceptability.

查看此版本解读 →查看此版本原文 ↗