跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.20103 · v1

Trading Parameters for Accuracy in MambaVision for Chest Radiograph Classification

首次提交 2026-11-16 00:24
版本更新 2026-11-16 00:24
雷达观测 2026-11-17 12:06
arXiv ↗PDF ↗

摘要

MambaVision, a hybrid state-space and attention backbone, places most of its parameters in its widest, fourth stage. We quantified what that stage contributes to multi-label chest radiograph classification. The fourth stage was replaced with lighter single-scan state-space blocks adapted from Spatial-Mamba, with multi-scale dilated depthwise convolutions applied to the scan output; the first three stages were retained. Tiny, Small, and Base models were evaluated across nine dataset-scale combinations drawn from two source cohorts: the National Institutes of Health ChestX-ray14 archive (full ChestMNIST and a high-resolution subset) and Indiana University Open-i. At the Tiny scale, replacement reduced parameter count by 35.7% and increased graphics processing unit throughput by 19.3%; the savings came from the stage's dense projections, not from removing quadratic attention. Without distillation, the mean area under the receiver operating characteristic curve on ChestMNIST was 0.004 lower than the baseline (95% bootstrap confidence interval, 0.002 to 0.006), and 0.003 to 0.006 lower across all nine combinations. Knowledge distillation from an unreplaced teacher narrowed the gap to the undistilled baseline to 0.001-0.002 and met the equivalence criterion on ChestMNIST, but distilling the baseline with the same recipe improved it by 0.001-0.003, so a gap of 0.002-0.005 persisted under symmetric training. At the Base scale, the unreplaced Small model was both smaller and more accurate. Fourth-stage replacement is a useful trade-off only for Tiny and Small models. These measurements let developers of chest radiograph screening tools weigh model size and speed against a quantified loss of diagnostic discrimination.

作者备注:10 pages, 4 figures, 9 tables. Submitted to an IEEE journal

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-16 00:24 · 最新观测版本

Trading Parameters for Accuracy in MambaVision for Chest Radiograph Classification

MambaVision, a hybrid state-space and attention backbone, places most of its parameters in its widest, fourth stage. We quantified what that stage contributes to multi-label chest radiograph classification. The fourth stage was replaced with lighter single-scan state-space blocks adapted from Spatial-Mamba, with multi-scale dilated depthwise convolutions applied to the scan output; the first three stages were retained. Tiny, Small, and Base models were evaluated across nine dataset-scale combinations drawn from two source cohorts: the National Institutes of Health ChestX-ray14 archive (full ChestMNIST and a high-resolution subset) and Indiana University Open-i. At the Tiny scale, replacement reduced parameter count by 35.7% and increased graphics processing unit throughput by 19.3%; the savings came from the stage's dense projections, not from removing quadratic attention. Without distillation, the mean area under the receiver operating characteristic curve on ChestMNIST was 0.004 lower than the baseline (95% bootstrap confidence interval, 0.002 to 0.006), and 0.003 to 0.006 lower across all nine combinations. Knowledge distillation from an unreplaced teacher narrowed the gap to the undistilled baseline to 0.001-0.002 and met the equivalence criterion on ChestMNIST, but distilling the baseline with the same recipe improved it by 0.001-0.003, so a gap of 0.002-0.005 persisted under symmetric training. At the Base scale, the unreplaced Small model was both smaller and more accurate. Fourth-stage replacement is a useful trade-off only for Tiny and Small models. These measurements let developers of chest radiograph screening tools weigh model size and speed against a quantified loss of diagnostic discrimination.

查看此版本解读 →查看此版本原文 ↗