跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.20613 · v1

Noise-Aware Testing of NISQ Quantum Programs: Self-Baseline Oracle with a Controlled False-Positive Rate

首次提交 2026-11-16 14:38
版本更新 2026-11-16 14:38
雷达观测 2026-11-17 13:07
arXiv ↗PDF ↗

摘要

Testing quantum programs on Noisy Intermediate-Scale Quantum (NISQ) devices faces a test-oracle problem: hardware noise and finite-shot sampling make the runs of a correct program vary as much as those of a faulty one, so oracles with a fixed acceptance threshold produce false positives that depend on the program and the backend. We present a noise-aware testing framework built on self-baseline calibration: each run of the program under test is compared with repeated executions of a trusted reference program on the same backend, and the acceptance threshold is the (1−α)(1-α) quantile of the finite-shot null distribution of the Jensen-Shannon divergence, so the oracle's false-positive rate is a level set in advance. A noncentral chi-square model predicts detection power, a homogeneity test and a two-run sentinel detect drift, a mutation engine labels every mutant exactly within a three-class noise-aware taxonomy, and zero-noise extrapolation attributes rejections to faults or noise. In simulation on nine core benchmarks, 32 QASMBench programs, ten real bugs, seven noise regimes and three device snapshots, the oracle's false-positive rate is 0.0011 at α=10−3α= 10^{-3} over 9,000 correct runs, against 36-74% for fixed thresholds, 8.9% for a QOIN-style filter and 10.8% for a globally calibrated threshold, while attaining the highest F1 on non-equivalent faults (0.941). On an IBM Heron device, using about 14 minutes of QPU time, it rejected none of 82 correct runs and detected 120 of 121 faults and semantic mutants, and a two-run sentinel reduced drift-induced false positives from 27.4% to 1.8%.

作者备注:53 pages, 7 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-16 14:38 · 最新观测版本

Noise-Aware Testing of NISQ Quantum Programs: Self-Baseline Oracle with a Controlled False-Positive Rate

Testing quantum programs on Noisy Intermediate-Scale Quantum (NISQ) devices faces a test-oracle problem: hardware noise and finite-shot sampling make the runs of a correct program vary as much as those of a faulty one, so oracles with a fixed acceptance threshold produce false positives that depend on the program and the backend. We present a noise-aware testing framework built on self-baseline calibration: each run of the program under test is compared with repeated executions of a trusted reference program on the same backend, and the acceptance threshold is the (1−α)(1-α) quantile of the finite-shot null distribution of the Jensen-Shannon divergence, so the oracle's false-positive rate is a level set in advance. A noncentral chi-square model predicts detection power, a homogeneity test and a two-run sentinel detect drift, a mutation engine labels every mutant exactly within a three-class noise-aware taxonomy, and zero-noise extrapolation attributes rejections to faults or noise. In simulation on nine core benchmarks, 32 QASMBench programs, ten real bugs, seven noise regimes and three device snapshots, the oracle's false-positive rate is 0.0011 at α=10−3α= 10^{-3} over 9,000 correct runs, against 36-74% for fixed thresholds, 8.9% for a QOIN-style filter and 10.8% for a globally calibrated threshold, while attaining the highest F1 on non-equivalent faults (0.941). On an IBM Heron device, using about 14 minutes of QPU time, it rejected none of 82 correct runs and detected 120 of 121 faults and semantic mutants, and a two-run sentinel reduced drift-induced false positives from 27.4% to 1.8%.

查看此版本解读 →查看此版本原文 ↗