摘要
The drive toward heterogeneous 2.5D chiplet packages promises unmatched performance and customization, yet the resulting density amplifies thermal challenges. To facilitate rapid design space exploration, we present ThermLeT, a multimodal transformer-based, scale invariant surrogate that integrates power density maps, spatial coordinate embeddings, material properties and heat transfer rate to predict steady state temperature in 13 ms, about four orders of magnitude faster than conventional finite element solvers such as ANSYS. To train the transformer model, we also create a dataset of 6,221 chiplet layouts perturbed from three representative architectures. On a 150 sample test set, ThermLeT achieves an RMSE of 3.16°C and an MAE of 2.24°C, improving accuracy by 35% over ThermEDGe and by 71% over HotSpot, while running approximately 6x and 11x lower inference latencies respectively. Ablation studies confirm robust generalization to unseen floorplans. Code and dataset available at https://github.com/MicroSystemsDesignLab/ThermLeT
作者备注:Published at VLSID 2026. Code and dataset: https://github.com/MicroSystemsDesignLab/ThermLeT
期刊信息:VLSID 2026, pp. 512-517
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-17 06:36 · 最新观测版本
ThermLeT: Transformer-based Temperature Prediction for 2.5D Chiplet Architecture
The drive toward heterogeneous 2.5D chiplet packages promises unmatched performance and customization, yet the resulting density amplifies thermal challenges. To facilitate rapid design space exploration, we present ThermLeT, a multimodal transformer-based, scale invariant surrogate that integrates power density maps, spatial coordinate embeddings, material properties and heat transfer rate to predict steady state temperature in 13 ms, about four orders of magnitude faster than conventional finite element solvers such as ANSYS. To train the transformer model, we also create a dataset of 6,221 chiplet layouts perturbed from three representative architectures. On a 150 sample test set, ThermLeT achieves an RMSE of 3.16°C and an MAE of 2.24°C, improving accuracy by 35% over ThermEDGe and by 71% over HotSpot, while running approximately 6x and 11x lower inference latencies respectively. Ablation studies confirm robust generalization to unseen floorplans. Code and dataset available at https://github.com/MicroSystemsDesignLab/ThermLeT
查看此版本解读 →查看此版本原文 ↗