跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.22117 · v1

RetiDual-Select: Reliability-Aware Specialist-Generalist Routing for Retinal OCT under Image-Quality Shift

首次提交 2026-11-17 10:59
版本更新 2026-11-17 10:59
雷达观测 2026-11-18 19:43
arXiv ↗PDF ↗

摘要

Adaptive fusion can repair a static ensemble's errors, but can also overturn correct decisions. RetiDual-Select combines retinal specialist RETFound with the image encoder of the medical vision-language model MedSigLIP, separating candidate fusion, routing safety and predictive review. Calibrated product-of-experts (PoE) fusion is the static reference, a small gate proposes an alternative for each image, a validation-frozen harm guard decides whether that candidate may replace the reference, and a separate score prioritizes review. Static PoE reached the highest or joint-highest clean accuracy on all three datasets. At a clean 2% accepted-error target the review policy accepted 94.3% of Kermany-4 images at 99.89% selective accuracy, and 92.4% of OCT-C8 at 98.65%. Both branches were correct on 95.0% and 91.8% of clean images; only 4.4% and 6.2% had exactly one correct branch. Across 15 prespecified synthetic conditions, adaptive gains were concentrated in severe contrast reduction, where this routing opportunity widened roughly ninefold; percentile rescaling largely removed the effect, linking it to compressed dynamic range. In post-hoc validation-only analyses, gain was higher when the gate followed the more reliable branch, and a frozen guard cut the worst-condition OCT-C8 loss from 1.39 to 0.36 percentage points. Adaptive routing was useful when image quality created a reliability opportunity and the gate followed it; otherwise the system retained Static PoE or deferred for review. The findings are bounded by the synthetic perturbations evaluated and do not establish robustness to natural acquisition or scanner shift.

作者备注:4 figures, 4 tables, 42 references. Submitted to the IEEE for possible publication. Main article only; the separate Supplementary Information is not included

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-17 10:59 · 最新观测版本

RetiDual-Select: Reliability-Aware Specialist-Generalist Routing for Retinal OCT under Image-Quality Shift

Adaptive fusion can repair a static ensemble's errors, but can also overturn correct decisions. RetiDual-Select combines retinal specialist RETFound with the image encoder of the medical vision-language model MedSigLIP, separating candidate fusion, routing safety and predictive review. Calibrated product-of-experts (PoE) fusion is the static reference, a small gate proposes an alternative for each image, a validation-frozen harm guard decides whether that candidate may replace the reference, and a separate score prioritizes review. Static PoE reached the highest or joint-highest clean accuracy on all three datasets. At a clean 2% accepted-error target the review policy accepted 94.3% of Kermany-4 images at 99.89% selective accuracy, and 92.4% of OCT-C8 at 98.65%. Both branches were correct on 95.0% and 91.8% of clean images; only 4.4% and 6.2% had exactly one correct branch. Across 15 prespecified synthetic conditions, adaptive gains were concentrated in severe contrast reduction, where this routing opportunity widened roughly ninefold; percentile rescaling largely removed the effect, linking it to compressed dynamic range. In post-hoc validation-only analyses, gain was higher when the gate followed the more reliable branch, and a frozen guard cut the worst-condition OCT-C8 loss from 1.39 to 0.36 percentage points. Adaptive routing was useful when image quality created a reliability opportunity and the gate followed it; otherwise the system retained Static PoE or deferred for review. The findings are bounded by the synthetic perturbations evaluated and do not establish robustness to natural acquisition or scanner shift.

查看此版本解读 →查看此版本原文 ↗