跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.22556 · v1

Strong Fused Performance Can Mask Branch Collapse in a Dual-View Heart-Sound Classifier: A Three-Part Diagnostic Protocol

首次提交 2026-11-17 18:44
版本更新 2026-11-17 18:44
雷达观测 2026-11-18 11:33
arXiv ↗PDF ↗

摘要

Fusion models are usually judged by their fused score, a practice that assumes that every branch has learned something useful. We show that this assumption can fail silently in dual-view heart-sound classification. In AudioFuse, which fuses a spectrogram transformer with a waveform CNN, the spectrogram branch is unused despite strong fused performance when both branches are trained from scratch. We introduce a three-part diagnostic for branch collapse: whether deleting a branch changes the fused score, whether a linear probe on its features beats an untrained copy of the same branch, and whether the branch can learn its view when trained alone. Deleting the branch has negligible effect, and probing its features shows little improvement over an identically initialised, untrained copy. Yet the same architecture trained alone exceeds 0.9 AUC, so its view is learnable, while the jointly trained model is near chance when it must rely on this branch. Update statistics and an initialisation experiment point to an early optimisation imbalance. Moving a strong artificial label cue from one input to the other can switch which branch the model relies on, even though the branch architectures stay the same. We observe branch collapse on PhysioNet, but the full diagnostic is not met on ICBHI or CirCor. Fused performance alone therefore cannot establish that every branch learned a meaningful representation, and we recommend reporting branch deletion and an untrained-control probe alongside it.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-17 18:44 · 最新观测版本

Strong Fused Performance Can Mask Branch Collapse in a Dual-View Heart-Sound Classifier: A Three-Part Diagnostic Protocol

Fusion models are usually judged by their fused score, a practice that assumes that every branch has learned something useful. We show that this assumption can fail silently in dual-view heart-sound classification. In AudioFuse, which fuses a spectrogram transformer with a waveform CNN, the spectrogram branch is unused despite strong fused performance when both branches are trained from scratch. We introduce a three-part diagnostic for branch collapse: whether deleting a branch changes the fused score, whether a linear probe on its features beats an untrained copy of the same branch, and whether the branch can learn its view when trained alone. Deleting the branch has negligible effect, and probing its features shows little improvement over an identically initialised, untrained copy. Yet the same architecture trained alone exceeds 0.9 AUC, so its view is learnable, while the jointly trained model is near chance when it must rely on this branch. Update statistics and an initialisation experiment point to an early optimisation imbalance. Moving a strong artificial label cue from one input to the other can switch which branch the model relies on, even though the branch architectures stay the same. We observe branch collapse on PhysioNet, but the full diagnostic is not met on ICBHI or CirCor. Fused performance alone therefore cannot establish that every branch learned a meaningful representation, and we recommend reporting branch deletion and an untrained-control probe alongside it.

查看此版本解读 →查看此版本原文 ↗