摘要
Efficient control of underfloor heating (UFH) systems coupled with heat pumps (HPs) is challenging due to the high thermal inertia of buildings and the slow dynamic response of UFH systems. Deep Reinforcement Learning (DRL) offers a data-driven control approach capable of simultaneously optimizing energy consumption and thermal comfort. However, the application of DRL-based controllers in occupied buildings under real operating conditions remains limited. This work presents and end-to-end case study (development, evaluation, and real-world deployment) of a DRL-based controller for an integrated UFH-HP system. First, a simulation-based pilot study was conducted to assess different DRL algorithms, control strategies, and configurations. Subsequently, a digital twin of a real residential building was developed and used to train DRL agents under simulated operating conditions. The best-performing agent was then deployed in the physical building without additional online fine-tuning. The results show that the controller successfully maintained indoor temperatures within the prescribed comfort limits while dynamically adjusting the HP supply temperature and UFH valve positions. These findings demonstrate the feasibility of deploying DRL controllers in occupied buildings and highlight their robustness and the practical challenges associated with transferring control policies from digital environments to real heating systems.
作者备注:Preprint submited to journal
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-18 00:54 · 最新观测版本
Deep Reinforcement Learning for Heat Pump and Underfloor Heating Control: An End-to-End Case Study
Efficient control of underfloor heating (UFH) systems coupled with heat pumps (HPs) is challenging due to the high thermal inertia of buildings and the slow dynamic response of UFH systems. Deep Reinforcement Learning (DRL) offers a data-driven control approach capable of simultaneously optimizing energy consumption and thermal comfort. However, the application of DRL-based controllers in occupied buildings under real operating conditions remains limited. This work presents and end-to-end case study (development, evaluation, and real-world deployment) of a DRL-based controller for an integrated UFH-HP system. First, a simulation-based pilot study was conducted to assess different DRL algorithms, control strategies, and configurations. Subsequently, a digital twin of a real residential building was developed and used to train DRL agents under simulated operating conditions. The best-performing agent was then deployed in the physical building without additional online fine-tuning. The results show that the controller successfully maintained indoor temperatures within the prescribed comfort limits while dynamically adjusting the HP supply temperature and UFH valve positions. These findings demonstrate the feasibility of deploying DRL controllers in occupied buildings and highlight their robustness and the practical challenges associated with transferring control policies from digital environments to real heating systems.
查看此版本解读 →查看此版本原文 ↗