跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.23862 · v1

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

首次提交 2026-11-18 13:09
版本更新 2026-11-18 13:09
雷达观测 2026-11-19 19:08
arXiv ↗PDF ↗

摘要

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

作者备注:25 pages, 13 figures, 4 tables

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-18 13:09 · 最新观测版本

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

查看此版本解读 →查看此版本原文 ↗