Towards Vacuum-Assisted Robotic Needle Interventions: From Fluid Aspiration to Tissue Biopsy

首次提交 2026-11-18 19:40
版本更新 2026-11-18 19:40
雷达观测 2026-11-19 15:04
arXiv ↗PDF ↗

摘要

Robotic ultrasound-guided needle interventions have primarily focused on target localization and accurate needle placement, while the subsequent acquisition of diagnostic material remains comparatively underexplored. Moreover, pleural fluid aspiration and tissue biopsy are typically addressed as separate procedures, despite sharing common requirements for ultrasound guidance, safe access, and sample transport. This work presents a unified robotic framework for ultrasound-guided fluid and tissue extraction using a single vacuum-assisted end effector. The proposed system combines force controlled ultrasound scanning, semantic target identification, automated needle deployment, and procedure specific material acquisition. A coaxial needle assembly and shared pump assisted pathway enable direct pleural fluid aspiration, while controlled cannula actuation provides the additional cutting action required for solid-tissue acquisition. End-to-end evaluation using a Franka Emika Panda robot over 50 phantom trials achieved successful extraction in 23/25 pleural fluid aspiration trials (92\%) and 22/25 tissue acquisition trials (88\%). Following successful tissue-target access, acquisition and transport were completed in all 22 trials.

作者备注:8 pages, 8 figures, Submitted to the 2027 IEEE International Conference on Robotics and Automation (ICRA)

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-18 19:40 · 最新观测版本

Towards Vacuum-Assisted Robotic Needle Interventions: From Fluid Aspiration to Tissue Biopsy

Robotic ultrasound-guided needle interventions have primarily focused on target localization and accurate needle placement, while the subsequent acquisition of diagnostic material remains comparatively underexplored. Moreover, pleural fluid aspiration and tissue biopsy are typically addressed as separate procedures, despite sharing common requirements for ultrasound guidance, safe access, and sample transport. This work presents a unified robotic framework for ultrasound-guided fluid and tissue extraction using a single vacuum-assisted end effector. The proposed system combines force controlled ultrasound scanning, semantic target identification, automated needle deployment, and procedure specific material acquisition. A coaxial needle assembly and shared pump assisted pathway enable direct pleural fluid aspiration, while controlled cannula actuation provides the additional cutting action required for solid-tissue acquisition. End-to-end evaluation using a Franka Emika Panda robot over 50 phantom trials achieved successful extraction in 23/25 pleural fluid aspiration trials (92\%) and 22/25 tissue acquisition trials (88\%). Following successful tissue-target access, acquisition and transport were completed in all 22 trials.