← 研踪 PaperTrailarXiv:2611.24323 · v1
RespCCT and FreqCCT: Compact, Explainable and Cost-Aware Convolutional Transformers for Multi-Class Respiratory Disease Classification
首次提交 2026-11-18 20:26
版本更新 2026-11-18 20:26
雷达观测 2026-11-19 15:04
摘要
Chest auscultation depends on the listener, and software that classifies lung sounds could give a second reading where trained listeners are scarce. The most accurate published classifiers fine-tune large pretrained networks, and their accuracy is rarely reported with running cost or paired statistics. This study makes three contributions. (i) It proposes RespCCT and FreqCCT, two compact convolutional transformers of 173,187 and 124,999 parameters that learn from random initialization on mel, constant-Q and cepstral images of 5 s frames from three public databases, ICBHI, KAUH and RD@TR, with 1,665 audio files in seven classes. (ii) It compares both models with five ImageNet-pretrained networks and larger distilled variants on one test set, using paired bootstrap intervals. (iii) It measures the cost of every pipeline stage on one CPU thread, tests whether attribution maps depend on the trained weights, and probes whether the learned features reveal the recording source. On the test fold, RespCCT reaches an accuracy of 98.13% and a macro F1 of 0.970, and FreqCCT reaches 97.58% and 0.951. Over five folds, RespCCT with three seeds reaches 97.65% and 0.959, and FreqCCT with one seed reaches 96.95% and 0.941. The two strongest pretrained networks reach a macro F1 of 0.984, whereas RespCCT needs 2.0 to 64.6 times less weight storage. Computing the three input images takes longer than running either model, and a linear probe identifies the source database with 0.958 accuracy. A team can weigh accuracy against storage and time before device testing.
作者备注:22 pages. Manuscript to be submitted to Biomedical Signal Processing and Control
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-18 20:26 · 最新观测版本
RespCCT and FreqCCT: Compact, Explainable and Cost-Aware Convolutional Transformers for Multi-Class Respiratory Disease Classification
Chest auscultation depends on the listener, and software that classifies lung sounds could give a second reading where trained listeners are scarce. The most accurate published classifiers fine-tune large pretrained networks, and their accuracy is rarely reported with running cost or paired statistics. This study makes three contributions. (i) It proposes RespCCT and FreqCCT, two compact convolutional transformers of 173,187 and 124,999 parameters that learn from random initialization on mel, constant-Q and cepstral images of 5 s frames from three public databases, ICBHI, KAUH and RD@TR, with 1,665 audio files in seven classes. (ii) It compares both models with five ImageNet-pretrained networks and larger distilled variants on one test set, using paired bootstrap intervals. (iii) It measures the cost of every pipeline stage on one CPU thread, tests whether attribution maps depend on the trained weights, and probes whether the learned features reveal the recording source. On the test fold, RespCCT reaches an accuracy of 98.13% and a macro F1 of 0.970, and FreqCCT reaches 97.58% and 0.951. Over five folds, RespCCT with three seeds reaches 97.65% and 0.959, and FreqCCT with one seed reaches 96.95% and 0.941. The two strongest pretrained networks reach a macro F1 of 0.984, whereas RespCCT needs 2.0 to 64.6 times less weight storage. Computing the three input images takes longer than running either model, and a linear probe identifies the source database with 0.958 accuracy. A team can weigh accuracy against storage and time before device testing.
查看此版本解读 →查看此版本原文 ↗