← 研踪 PaperTrailarXiv:2611.24776 · v1
4D-TEMPO: Differentiable 4D-STEM ptychography via fast Physics Optimizers
首次提交 2026-11-19 01:23
版本更新 2026-11-19 01:23
雷达观测 2026-11-19 15:04
摘要
Electron ptychography recovers atomic structure from 4D-STEM data: diffraction patterns at multiple positions of a scanned probe. Current codes reconstruct an image and read atoms off it, or fit atoms under an loss; neither gives per-atom uncertainty. We propose 4D-TEMPO, a differentiable physical renderer that fits the atoms, the microscope, and the detector directly to the recorded electron counts under a Poisson likelihood. The output is a list of atoms, each a Gaussian primitive with a 3D position, a thermal width, and a model-conditional error bar from the Fisher information. The Fisher information also conditions the solver, gives the dose (electrons per Å) each parameter needs, and separates calibration from imaging. On a simulated WSe bilayer, starting from the published reconstruction, fitted atoms cut in-plane error by a third (3.2 vs. 4.8 pm) and depth error by 40-61% against its 3D peaks. Depth comes from multiple scattering into the dark field, the faint counts outside the direct beam. The two layers, closer than the depth of field, separate; per-atom depth then follows the layer geometry. When the model is well specified, the bars are calibrated (69% of position coordinates within ). On experimental WSe, fitted atoms predict held-out patterns better than the three published codes we test. With free probe modes where atoms are incomplete, the same likelihood predicts best on all three held-out benchmarks, matches every WSe baseline in 5 min against up to 20.5 h, and passes torchslice at its released setting 180 sooner on PrScO. Per-atom error bars, planned doses, and fast reconstruction point to low-dose, real-time 3D imaging of beam-sensitive and dynamic materials.
作者备注:34 pages: 8-page paper, references, and 23-page supplementary material; 10 figures, 10 tables
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-19 01:23 · 最新观测版本
4D-TEMPO: Differentiable 4D-STEM ptychography via fast Physics Optimizers
Electron ptychography recovers atomic structure from 4D-STEM data: diffraction patterns at multiple positions of a scanned probe. Current codes reconstruct an image and read atoms off it, or fit atoms under an loss; neither gives per-atom uncertainty. We propose 4D-TEMPO, a differentiable physical renderer that fits the atoms, the microscope, and the detector directly to the recorded electron counts under a Poisson likelihood. The output is a list of atoms, each a Gaussian primitive with a 3D position, a thermal width, and a model-conditional error bar from the Fisher information. The Fisher information also conditions the solver, gives the dose (electrons per Å) each parameter needs, and separates calibration from imaging. On a simulated WSe bilayer, starting from the published reconstruction, fitted atoms cut in-plane error by a third (3.2 vs. 4.8 pm) and depth error by 40-61% against its 3D peaks. Depth comes from multiple scattering into the dark field, the faint counts outside the direct beam. The two layers, closer than the depth of field, separate; per-atom depth then follows the layer geometry. When the model is well specified, the bars are calibrated (69% of position coordinates within ). On experimental WSe, fitted atoms predict held-out patterns better than the three published codes we test. With free probe modes where atoms are incomplete, the same likelihood predicts best on all three held-out benchmarks, matches every WSe baseline in 5 min against up to 20.5 h, and passes torchslice at its released setting 180 sooner on PrScO. Per-atom error bars, planned doses, and fast reconstruction point to low-dose, real-time 3D imaging of beam-sensitive and dynamic materials.
查看此版本解读 →查看此版本原文 ↗