跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.26391 · v1

Simulation-pretrained autoencoders versus PCA for compressing multimode fibre transmission matrices

首次提交 2026-11-20 00:45
版本更新 2026-11-20 00:45
雷达观测 2026-11-20 12:52
arXiv ↗PDF ↗

摘要

Multimode optical fibres can image through a thin, flexible probe once their transmission matrix (TM) has been measured, but a TM is large and must be re-measured whenever the fibre moves. A compact model of feasible TMs would make storing and re-estimating them cheaper, so we ask how compactly TMs can be represented, and from how few measured TMs. Here we benchmark a permutation-equivariant autoencoder, pretrained on simulated fibres and adapted to measured TMs, against principal component analysis (PCA). At 62x compression, adapting the pretrained autoencoder with just two measured TMs reconstructs the TM of a 50um fibre well enough to focus light at 98% of the ideal enhancement, and it stays accurate when the TMs are shifted by 25 pixels or zoomed by 10%, which quickly degrades a linear basis. It is not, however, a better compressor: PCA is about ten times more accurate when fitted on all 163 real TMs (1.1% against 11.9% error on held-out TMs) and is already more accurate from ten. The autoencoder's value is as a prior when few or no real TMs exist: with none it reaches 29% error, against 91% for PCA fitted on the same simulation. Transfer to a different fibre is only partial. The most important extension, not yet tested, is to recover pixel-basis TMs from fewer measurements than a full TM, which would turn the pretrained prior from a compressor into a measurement-saving tool.

作者备注:31 pages, 14 figures, including supplementary material. Code, trained weights and data are linked in the Data and code availability section

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-20 00:45 · 最新观测版本

Simulation-pretrained autoencoders versus PCA for compressing multimode fibre transmission matrices

Multimode optical fibres can image through a thin, flexible probe once their transmission matrix (TM) has been measured, but a TM is large and must be re-measured whenever the fibre moves. A compact model of feasible TMs would make storing and re-estimating them cheaper, so we ask how compactly TMs can be represented, and from how few measured TMs. Here we benchmark a permutation-equivariant autoencoder, pretrained on simulated fibres and adapted to measured TMs, against principal component analysis (PCA). At 62x compression, adapting the pretrained autoencoder with just two measured TMs reconstructs the TM of a 50um fibre well enough to focus light at 98% of the ideal enhancement, and it stays accurate when the TMs are shifted by 25 pixels or zoomed by 10%, which quickly degrades a linear basis. It is not, however, a better compressor: PCA is about ten times more accurate when fitted on all 163 real TMs (1.1% against 11.9% error on held-out TMs) and is already more accurate from ten. The autoencoder's value is as a prior when few or no real TMs exist: with none it reaches 29% error, against 91% for PCA fitted on the same simulation. Transfer to a different fibre is only partial. The most important extension, not yet tested, is to recover pixel-basis TMs from fewer measurements than a full TM, which would turn the pretrained prior from a compressor into a measurement-saving tool.

查看此版本解读 →查看此版本原文 ↗