← 研踪 PaperTrailarXiv:2611.28275 · v1
eSPG: The Unreasonable Effectiveness of Event Speckle Plethysmography
首次提交 2026-11-21 03:56
版本更新 2026-11-21 03:56
雷达观测 2026-11-24 11:43
摘要
Non-contact measurement of vital signs such as heart rate (HR) is valuable for patient monitoring and rescue operations. However, existing methods struggle with ambient illumination and motion, and have been demonstrated only at distances of tens of meters. Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera. Event cameras, with their high dynamic range, temporal resolution, and sensitivity to intensity changes, are well-suited to capturing rapid speckle fluctuations that encode the physiological signal, even under challenging illumination and imaging conditions. We demonstrate HR estimation at 1 km with a mean absolute error of 5 beats per minute, and 90% of estimates satisfy an AAMI-defined HR estimation criterion. This distance exceeds previous remote plethysmography demonstrations by an order of magnitude and previous speckle plethysmography demonstrations by over three orders of magnitude. We also study and characterize robustness to motion and ambient illumination. Our theoretical analysis and experimental results demonstrate that resolving dynamic speckle fluctuations enables accurate heart rate estimation even at kilometer-scale distances, establishing a new direction toward robust, non-contact physiological monitoring.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-21 03:56 · 最新观测版本
eSPG: The Unreasonable Effectiveness of Event Speckle Plethysmography
Non-contact measurement of vital signs such as heart rate (HR) is valuable for patient monitoring and rescue operations. However, existing methods struggle with ambient illumination and motion, and have been demonstrated only at distances of tens of meters. Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera. Event cameras, with their high dynamic range, temporal resolution, and sensitivity to intensity changes, are well-suited to capturing rapid speckle fluctuations that encode the physiological signal, even under challenging illumination and imaging conditions. We demonstrate HR estimation at 1 km with a mean absolute error of 5 beats per minute, and 90% of estimates satisfy an AAMI-defined HR estimation criterion. This distance exceeds previous remote plethysmography demonstrations by an order of magnitude and previous speckle plethysmography demonstrations by over three orders of magnitude. We also study and characterize robustness to motion and ambient illumination. Our theoretical analysis and experimental results demonstrate that resolving dynamic speckle fluctuations enables accurate heart rate estimation even at kilometer-scale distances, establishing a new direction toward robust, non-contact physiological monitoring.
查看此版本解读 →查看此版本原文 ↗