Non-contact measurement of vital signs such as heart rate (HR) is valuable for patient monitoring and rescue operations. However, existing methods struggle with ambient illumination and motion, and have been demonstrated only at distances of tens of meters. Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera. Event cameras, with their high dynamic range, temporal resolution, and sensitivity to intensity changes, are well-suited to capturing rapid speckle fluctuations that encode the physiological signal, even under challenging illumination and imaging conditions. We demonstrate HR estimation at 1 km with a mean absolute error of 5 beats per minute, and 90% of estimates satisfy an AAMI-defined HR estimation criterion. This distance exceeds previous remote plethysmography demonstrations by an order of magnitude and previous speckle plethysmography demonstrations by over three orders of magnitude. We also study and characterize robustness to motion and ambient illumination. Our theoretical analysis and experimental results demonstrate that resolving dynamic speckle fluctuations enables accurate heart rate estimation even at kilometer-scale distances, establishing a new direction toward robust, non-contact physiological monitoring.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-21 03:56 · 最新观测版本

eSPG: The Unreasonable Effectiveness of Event Speckle Plethysmography

Non-contact measurement of vital signs such as heart rate (HR) is valuable for patient monitoring and rescue operations. However, existing methods struggle with ambient illumination and motion, and have been demonstrated only at distances of tens of meters. Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera. Event cameras, with their high dynamic range, temporal resolution, and sensitivity to intensity changes, are well-suited to capturing rapid speckle fluctuations that encode the physiological signal, even under challenging illumination and imaging conditions. We demonstrate HR estimation at 1 km with a mean absolute error of 5 beats per minute, and 90% of estimates satisfy an AAMI-defined HR estimation criterion. This distance exceeds previous remote plethysmography demonstrations by an order of magnitude and previous speckle plethysmography demonstrations by over three orders of magnitude. We also study and characterize robustness to motion and ambient illumination. Our theoretical analysis and experimental results demonstrate that resolving dynamic speckle fluctuations enables accurate heart rate estimation even at kilometer-scale distances, establishing a new direction toward robust, non-contact physiological monitoring.

查看此版本解读 →查看此版本原文 ↗