摘要

Camera-LiDAR pairs installed as fixed infrastructure need periodic recalibration, but a calibration target takes the installation out of service. We present FGSCalib, a targetless method that calibrates a stationary camera-LiDAR pair from the objects moving in its view. We only assume that arbitrary moving objects are present in the scene: each sensor separates the moving foreground from the static background, without relying on object classes. With the correct extrinsic, the LiDAR foreground points project onto the camera foreground. FGSCalib turns the camera mask into a boundary-proximity field and finds the extrinsic by two-stage simulated annealing over selected frame pairs. It needs no measured initial extrinsic (random starts give similar results) and works with both rotating and non-repetitive LiDARs. We evaluate it on 21 simulated scenarios with exact ground truth and on 72 real ones (nine camera-LiDAR pairs in eight scenes), with a reference averaged from 43 manual calibrations. In simulation the median error is 5.3 cm and 0.19°. On real data we use a tolerance of 18 cm and 1.8°, met by 93% of single manual calibrations. Keeping the lowest-cost of five runs, FGSCalib meets it in 51 of the 72 scenarios: in 20 of 24 with the Livox, where the strongest of five baselines reaches 11, and in 31 of 48 with the two rotating LiDARs, where only one baseline estimate does. Its median error is 9.5 cm and 0.9°, against 7.3 cm and 0.7° for a single manual calibration. The code and the dataset are available online.

作者备注:12 pages, 5 figures, and 4 pages of supplementary material. Code: https://github.com/zsungi/fgscalib

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-24 00:20 · 最新观测版本

FGSCalib: Targetless Camera-LiDAR Extrinsic Calibration from Foreground Segmentation

Camera-LiDAR pairs installed as fixed infrastructure need periodic recalibration, but a calibration target takes the installation out of service. We present FGSCalib, a targetless method that calibrates a stationary camera-LiDAR pair from the objects moving in its view. We only assume that arbitrary moving objects are present in the scene: each sensor separates the moving foreground from the static background, without relying on object classes. With the correct extrinsic, the LiDAR foreground points project onto the camera foreground. FGSCalib turns the camera mask into a boundary-proximity field and finds the extrinsic by two-stage simulated annealing over selected frame pairs. It needs no measured initial extrinsic (random starts give similar results) and works with both rotating and non-repetitive LiDARs. We evaluate it on 21 simulated scenarios with exact ground truth and on 72 real ones (nine camera-LiDAR pairs in eight scenes), with a reference averaged from 43 manual calibrations. In simulation the median error is 5.3 cm and 0.19°. On real data we use a tolerance of 18 cm and 1.8°, met by 93% of single manual calibrations. Keeping the lowest-cost of five runs, FGSCalib meets it in 51 of the 72 scenarios: in 20 of 24 with the Livox, where the strongest of five baselines reaches 11, and in 31 of 48 with the two rotating LiDARs, where only one baseline estimate does. Its median error is 9.5 cm and 0.9°, against 7.3 cm and 0.7° for a single manual calibration. The code and the dataset are available online.

查看此版本解读 →查看此版本原文 ↗