跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.33577 · v1

DoseSteer: Steering diffusion-based dose prediction models towards clinical targets via Dual-Response Guidance

首次提交 2026-11-25 08:42
版本更新 2026-11-25 08:42
雷达观测 2026-11-26 10:24
arXiv ↗PDF ↗

摘要

AI dose-prediction models generate patient-specific 3D dose distributions from patient anatomy. Yet these predictions can still miss structure-level clinical dose targets. Once deployed, most existing predictors offer no direct mechanism to correct such deviations, deferring target enforcement to downstream plan optimization. We introduce DoseSteer, an inference-time framework that steers frozen diffusion-based dose prediction models towards specified clinical targets without retraining. To meet clinical targets while preserving overall dose prediction quality, we propose Dual-Response Guidance (DRG), a structure-centric algorithm that probes the model's responses to perturbations in each structure's noisy dose and context and jointly solves for per-structure steering strengths. Across five dataset-model configurations spanning three diffusion architectures and three datasets, DRG outperforms 12 training-free baselines under identical reference-derived target proxies, removing at least 97% of the target error, reducing the official dose error by 7.8% on average, and improving dose fidelity outside the steered structures. DoseSteer reconciles learned anatomical dose priors with explicit structure-level targets at test time, establishing a principled, training-free mechanism to refine AI dose predictions prior to plan optimization. Code is available at https://github.com/csp2002/DoseSteer.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-25 08:42 · 最新观测版本

DoseSteer: Steering diffusion-based dose prediction models towards clinical targets via Dual-Response Guidance

AI dose-prediction models generate patient-specific 3D dose distributions from patient anatomy. Yet these predictions can still miss structure-level clinical dose targets. Once deployed, most existing predictors offer no direct mechanism to correct such deviations, deferring target enforcement to downstream plan optimization. We introduce DoseSteer, an inference-time framework that steers frozen diffusion-based dose prediction models towards specified clinical targets without retraining. To meet clinical targets while preserving overall dose prediction quality, we propose Dual-Response Guidance (DRG), a structure-centric algorithm that probes the model's responses to perturbations in each structure's noisy dose and context and jointly solves for per-structure steering strengths. Across five dataset-model configurations spanning three diffusion architectures and three datasets, DRG outperforms 12 training-free baselines under identical reference-derived target proxies, removing at least 97% of the target error, reducing the official dose error by 7.8% on average, and improving dose fidelity outside the steered structures. DoseSteer reconciles learned anatomical dose priors with explicit structure-level targets at test time, establishing a principled, training-free mechanism to refine AI dose predictions prior to plan optimization. Code is available at https://github.com/csp2002/DoseSteer.

查看此版本解读 →查看此版本原文 ↗