跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.33589 · v1

Amortizing Exact Orthogonality: Drift-Triggered Restoration for Orthogonal Fine-Tuning

首次提交 2026-11-25 08:58
版本更新 2026-11-25 08:58
雷达观测 2026-11-26 10:24
arXiv ↗PDF ↗

摘要

Orthogonal finetuning (OFT) adapts a pretrained weight by an orthogonal transform and preserves its singular values and row angles, but existing methods construct an exact or approximate orthogonal transform at every optimization step. We measure how far a transform AA is from orthogonal by its orthogonality defect ∥A⊤A−I∥2\|A^\top A-I\|_2. For OFTv2, which truncates a Cayley-Neumann series, we show that the truncation order does not determine the defect. At its default order, block defects in checkpoints from the reference implementation span five orders of magnitude. We propose Restarted Tangent Orthogonal Finetuning (RTOFT), which uses the first-order update W(I+S)W(I+S) of a weight WW with a skew-symmetric SS and restores exact orthogonality by a polar decomposition only when the drift ∥S∥2\|S\|_2 reaches a tolerance ττ. The defect of I+SI+S is exactly ∥S∥22\|S\|_2^2. Therefore, reading the drift after every update and restoring before the next forward pass guarantees a defect of at most τ2τ^2 in every forward pass, independently of the loss, data, model, and optimizer. A final restoration makes the returned transform exactly orthogonal. On GLUE, RTOFT reduces the training time of block-diagonal, subspace, and butterfly parameterizations from 1.101.10-1.58×1.58\times to 0.970.97-1.13×1.13\times that of LoRA, and its block-diagonal version exceeds LoRA by 1.98±0.391.98\pm0.39 points on the six-task average over five seeds. At τ=0.10τ=0.10, the largest drift read during training stays between 0.100.10 and 0.120.12 across DeBERTaV3, Qwen, and diffusion models, whereas it ranges from 0.170.17 to 1.651.65 when restoring once per epoch. In all seven settings of our ablation, the tangent update is worse without restoration than with it, and restoring after every step yields no measurable accuracy gain over restoring at the tolerance and costs 4.54.5-27.5%27.5\% more per step.

作者备注:44 pages

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-25 08:58 · 最新观测版本

Amortizing Exact Orthogonality: Drift-Triggered Restoration for Orthogonal Fine-Tuning

Orthogonal finetuning (OFT) adapts a pretrained weight by an orthogonal transform and preserves its singular values and row angles, but existing methods construct an exact or approximate orthogonal transform at every optimization step. We measure how far a transform AA is from orthogonal by its orthogonality defect ∥A⊤A−I∥2\|A^\top A-I\|_2. For OFTv2, which truncates a Cayley-Neumann series, we show that the truncation order does not determine the defect. At its default order, block defects in checkpoints from the reference implementation span five orders of magnitude. We propose Restarted Tangent Orthogonal Finetuning (RTOFT), which uses the first-order update W(I+S)W(I+S) of a weight WW with a skew-symmetric SS and restores exact orthogonality by a polar decomposition only when the drift ∥S∥2\|S\|_2 reaches a tolerance ττ. The defect of I+SI+S is exactly ∥S∥22\|S\|_2^2. Therefore, reading the drift after every update and restoring before the next forward pass guarantees a defect of at most τ2τ^2 in every forward pass, independently of the loss, data, model, and optimizer. A final restoration makes the returned transform exactly orthogonal. On GLUE, RTOFT reduces the training time of block-diagonal, subspace, and butterfly parameterizations from 1.101.10-1.58×1.58\times to 0.970.97-1.13×1.13\times that of LoRA, and its block-diagonal version exceeds LoRA by 1.98±0.391.98\pm0.39 points on the six-task average over five seeds. At τ=0.10τ=0.10, the largest drift read during training stays between 0.100.10 and 0.120.12 across DeBERTaV3, Qwen, and diffusion models, whereas it ranges from 0.170.17 to 1.651.65 when restoring once per epoch. In all seven settings of our ablation, the tangent update is worse without restoration than with it, and restoring after every step yields no measurable accuracy gain over restoring at the tolerance and costs 4.54.5-27.5%27.5\% more per step.

查看此版本解读 →查看此版本原文 ↗