跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.33821 · v1

RadOncGym: An Agent-Based Framework for Radiotherapy Dose-Mimicking Optimization

首次提交 2026-11-25 13:50
版本更新 2026-11-25 13:50
雷达观测 2026-11-26 11:26
arXiv ↗PDF ↗

摘要

AI dose-prediction models generate patient-specific 3D dose distributions from patient anatomy, providing an important intermediate representation for automated radiotherapy planning. However, an AI-predicted dose must undergo downstream optimization to produce a physically constrained treatment plan, a process that requires balancing competing planning objectives. We present RadOncGym, an agent-based framework that enables an LLM agent to iteratively tune 12 planning-objective weights for dose-mimicking optimization. To reduce iterative evaluation cost, RadOncGym incorporates a surrogate verifier that provides rapid feedback while allowing the agent to decide when to request a full planning solve within a fixed solve budget. We evaluate RadOncGym on 60 OpenKBP head-and-neck patients, each paired with 10 predictions from OpenKBP-Opt dose-prediction sets, yielding 600 patient-prediction contexts per experimental configuration. Under RadOncGym's 16-turn setting with a three-solve budget, a GPT-5.6 Sol agent reduces mean clinical-criterion violation by 0.6131 Gy and improves DVH and dose scores by 0.5986 and 0.2204 Gy relative to leaving all 12 weights fixed at 1, outperforming all evaluated non-agent weight-tuning methods under the same solve budget. It remains competitive with the 16-solve variants of these methods while requiring 75.0-77.6% less normalized runtime. RadOncGym demonstrates the potential of LLM agents as optimization planners in downstream radiotherapy plan optimization and provides a public testbed for their systematic evaluation. Code and configurations are available at https://github.com/miaot-usc/RadOncGym.

作者备注:Accepted to WACV 2027

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-25 13:50 · 最新观测版本

RadOncGym: An Agent-Based Framework for Radiotherapy Dose-Mimicking Optimization

AI dose-prediction models generate patient-specific 3D dose distributions from patient anatomy, providing an important intermediate representation for automated radiotherapy planning. However, an AI-predicted dose must undergo downstream optimization to produce a physically constrained treatment plan, a process that requires balancing competing planning objectives. We present RadOncGym, an agent-based framework that enables an LLM agent to iteratively tune 12 planning-objective weights for dose-mimicking optimization. To reduce iterative evaluation cost, RadOncGym incorporates a surrogate verifier that provides rapid feedback while allowing the agent to decide when to request a full planning solve within a fixed solve budget. We evaluate RadOncGym on 60 OpenKBP head-and-neck patients, each paired with 10 predictions from OpenKBP-Opt dose-prediction sets, yielding 600 patient-prediction contexts per experimental configuration. Under RadOncGym's 16-turn setting with a three-solve budget, a GPT-5.6 Sol agent reduces mean clinical-criterion violation by 0.6131 Gy and improves DVH and dose scores by 0.5986 and 0.2204 Gy relative to leaving all 12 weights fixed at 1, outperforming all evaluated non-agent weight-tuning methods under the same solve budget. It remains competitive with the 16-solve variants of these methods while requiring 75.0-77.6% less normalized runtime. RadOncGym demonstrates the potential of LLM agents as optimization planners in downstream radiotherapy plan optimization and provides a public testbed for their systematic evaluation. Code and configurations are available at https://github.com/miaot-usc/RadOncGym.

查看此版本解读 →查看此版本原文 ↗