跳到正文
研踪PaperTrail
← 研踪 PaperTrail

CVF · CVPR 2026:cvf:aba2ddb178a6ef311eaa9223c089112d · 记录 #1

Revisiting Pose Sensitivity in Splat-based Computed Tomography under Sparse-view Reconstruction

来源日期(仅到年份) 2026
来源记录日期 2026
雷达观测 2026-11-02 00:19
CVF · CVPR 2026 ↗PDF ↗

摘要

X-ray computed tomography (CT) reconstructs volumetric representations of objects from projection images obtained by transmitting X-rays through a target. Recent splat-based tomography, which represents a volume as a continuous distribution of 3D Gaussians, has demonstrated both high reconstruction quality and fast convergence in cone-beam sparse-view CT. However, when deployed in real CT systems with limited and non-uniform view distributions, we observe distinctive streak and strip artifacts that are far more pronounced than in conventional reconstruction methods. Through detailed analysis, we show that these artifacts primarily originate from pose inaccuracies in the acquisition geometry rather than from view sparsity itself. We revisit pose sensitivity in the splatting formulation and derive a stable gradient-based framework that jointly refines geometric parameters during reconstruction. Our study not only identifies how pose perturbations propagate through the differentiable projection operator but also reveals why splat-based CT is particularly vulnerable to geometric misalignment. The resulting formulation remains lightweight and easily integrable into existing pipelines while substantially improving reconstruction fidelity under real-world sparse-view conditions.

论文发现出处

这些页面提供论文线索,不代表同行评审或质量认证。

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

发表信息与关联版本

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

平台记录号代表本站观测到的元数据变化,不是作者修订号。来源日期仅到月份或年份时,按该月或该年首日存档。

记录 #1 · 2026 · 最新观测版本

Revisiting Pose Sensitivity in Splat-based Computed Tomography under Sparse-view Reconstruction

X-ray computed tomography (CT) reconstructs volumetric representations of objects from projection images obtained by transmitting X-rays through a target. Recent splat-based tomography, which represents a volume as a continuous distribution of 3D Gaussians, has demonstrated both high reconstruction quality and fast convergence in cone-beam sparse-view CT. However, when deployed in real CT systems with limited and non-uniform view distributions, we observe distinctive streak and strip artifacts that are far more pronounced than in conventional reconstruction methods. Through detailed analysis, we show that these artifacts primarily originate from pose inaccuracies in the acquisition geometry rather than from view sparsity itself. We revisit pose sensitivity in the splatting formulation and derive a stable gradient-based framework that jointly refines geometric parameters during reconstruction. Our study not only identifies how pose perturbations propagate through the differentiable projection operator but also reveals why splat-based CT is particularly vulnerable to geometric misalignment. The resulting formulation remains lightweight and easily integrable into existing pipelines while substantially improving reconstruction fidelity under real-world sparse-view conditions.

查看此版本解读 →查看此版本原文 ↗