跳到正文
研踪PaperTrail
← 研踪 PaperTrail

CVF · CVPR 2026:cvf:e546c56dcb09bb21bee4490c1b3d817f · 记录 #1

MicroFM: Physics-guided Flow Matching for Isotropic Microscopy Reconstruction

来源日期(仅到年份) 2026
来源记录日期 2026
雷达观测 2026-11-05 02:00
CVF · CVPR 2026 ↗PDF ↗

摘要

Isotropic microscopy reconstruction remains challenging because the anisotropic point spread function in optical systems yields much poorer axial resolution and hampers accurate 3D analysis. Hardware strategies can approach isotropy, yet they are complex, costly, susceptible to sidelobes, and introduce phototoxicity. Deep learning approaches reduce acquisition burden, yet synthetic pipelines often rely on Gaussian blur mismatched to physical degradation, and many methods lack explicit volumetric geometry constraints as they process 2D slices independently, resulting in low-fidelity reconstructions. To address these challenges, we present MicroFM, which synthesizes realistic training data using physical PSFs matched to the target microscope. MicroFM also introduces a physics-guided flow-matching framework for isotropic microscopy reconstruction, guided by a continuous implicit geometry prior to achieve high-fidelity isotropic recovery. Across four fluorescence microscopy systems and datasets, MicroFM achieves state-of-the-art (SOTA) performance, producing sharper structures, more isotropic spectra, and substantial gains in both full-reference and no-reference metrics.

论文发现出处

这些页面提供论文线索,不代表同行评审或质量认证。

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

发表信息与关联版本

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

平台记录号代表本站观测到的元数据变化,不是作者修订号。来源日期仅到月份或年份时,按该月或该年首日存档。

记录 #1 · 2026 · 最新观测版本

MicroFM: Physics-guided Flow Matching for Isotropic Microscopy Reconstruction

Isotropic microscopy reconstruction remains challenging because the anisotropic point spread function in optical systems yields much poorer axial resolution and hampers accurate 3D analysis. Hardware strategies can approach isotropy, yet they are complex, costly, susceptible to sidelobes, and introduce phototoxicity. Deep learning approaches reduce acquisition burden, yet synthetic pipelines often rely on Gaussian blur mismatched to physical degradation, and many methods lack explicit volumetric geometry constraints as they process 2D slices independently, resulting in low-fidelity reconstructions. To address these challenges, we present MicroFM, which synthesizes realistic training data using physical PSFs matched to the target microscope. MicroFM also introduces a physics-guided flow-matching framework for isotropic microscopy reconstruction, guided by a continuous implicit geometry prior to achieve high-fidelity isotropic recovery. Across four fluorescence microscopy systems and datasets, MicroFM achieves state-of-the-art (SOTA) performance, producing sharper structures, more isotropic spectra, and substantial gains in both full-reference and no-reference metrics.

查看此版本解读 →查看此版本原文 ↗