Recent advances in 4D radar enable robust perception in adverse weather; however, the inherent sparsity, noise, and limited positional precision of radar point clouds pose significant challenges for registration-based odometry. In this letter, we propose RaDiVe, a 4D radar odometry framework that improves the accuracy and robustness of radar point cloud registration. We introduce a distance-bounded Normal Distributions Transform, which improves optimization stability and computational efficiency by restricting the correspondence search to near-distance voxel pairs. To mitigate measurement ambiguity, we propose a velocity-discrepancy point uncertainty model that weights each input 4D radar point according to the discrepancy between its measured Doppler radial velocity and the radial velocity predicted from the estimated ego-velocity. We also incorporate Signed Distance Function-based surface point extraction via implicit neural mapping to construct a geometrically consistent, noise-filtered local submap. Evaluations across multiple public datasets demonstrate that RaDiVe outperforms existing 4D radar odometry baselines by 44.4% in translational and 21.3% in rotational Absolute Trajectory Error on average, while maintaining real-time performance.
Wearable devices generate continuous physiological and behavioral data, but converting these signals into clinically reviewable biomarker hypotheses remains labor-intensive. We introduce CoDaS, an AI co-data-scientist that integrates multi-agent hypothesis generation, deterministic statistical analysis, adversarial validation and literature-grounded interpretation under human oversight. Across three wearable cohorts comprising 9,279 participant-observations, CoDaS prioritized candidate associations for mental-health and metabolic endpoints after internal checks for replication, stability, robustness and leakage. The system identified related circadian-instability signals associated with depression, including sleep-duration variability in DWB ($ρ$ = 0.252, $p$ < 0.001) and sleep-onset variability in GLOBEM ($ρ$ = 0.126, $p$ < 0.001), and derived a wearable cardiovascular-fitness index associated with insulin resistance (steps/resting heart rate; $ρ$ = -0.374, $p$ < 0.001). Adding these features to demographic models produced modest gains ($ΔR^2$ = 0.040 for depression, 0.021 for insulin resistance). In a 12-clinician review totaling approximately 25 active hours, clinician validity judgments aligned with CoDaS confidence tiers ($ρ$ = 0.67, $p$ = 0.005), whereas added clinical value and confidence to act were rated lower. CoDaS supports traceable, hypothesis-generating prioritization of wearable candidate biomarkers.