Where the Error Lives: Separating Lid-Edge and Body-Induced Error in Neural Pressure Prediction for 3D Cavity Flow
Zirun Zhou, Zhi-Qian Zhang, Yixuan Hong, Guang Liu, Zhigang Liu, Lili Zhang
原文摘要
Can a pressure surrogate score much better globally without better resolving the pressure around immersed bodies? We test this in a three-dimensional lid-driven cavity with an unregularized lid and centered pressure at native $128^3$ resolution. On 60 cases from 12 unseen geometries, with predictions sealed before the CFD truth existed, adding a body-free, Reynolds-conditioned reference correction to the same frozen $64^3$ surrogate lifted to $128^3$ lowers the mean full-volume relative $L_2$ error from 20.6% to 7.5%. In the post hoc regional analysis, the lid-edge junction occupies 1.5% of the fluid but holds 69% of the truth pressure energy and 95% of the uncorrected surrogate's squared error. Interior error changes by just +0.16% relative, and object-local peak error and recall change little on average. Retrospective ablations locate the learned term's contribution in the interior and near the bodies; rebasing on the reference lowers global error further with little change in cohort-mean near-body metrics. Reference-relative body-response error remains about 25% in the interior near-body band. Grid-refinement, lid-regularization and convergence checks delimit the numerical scope. In this benchmark, a large global gain chiefly reflects correction of a shared boundary field, not better resolution of the body response. We recommend reporting regional truth-energy and model-error shares alongside near-body and reference-relative body-response errors.
physics.flu-dyn · cs.LG