跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+93新增 AI 导读

arXiv 最近完成扫描:2026-11-16 01:34 · 全站最近入库:2026-11-14 15:09各信源进度 →

统计口径与数据新鲜度

统计 2026-11-15 07:53 — 2026-11-16 07:53(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-16 01:34最近发现新增版本:2026-11-14 15:09库内论文最新更新时间:2026-11-13 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

23,348 已收录论文19,580 AI 相关6,729 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-16 01:33(北京时间)
新论文 · v1arXiv:2611.15348

Breath-Dx: A Time Series Classification Benchmark for Disease Screening with eNose

Ivan Poddiakov, Ivan Kruzhilov, Galina Zubkova, Svetlana Erofeeva, Andrey Savchenko, Pavel Blinov

原文摘要

Electronic nose (eNose) technology offers a portable, non-invasive route for disease screening via exhaled breath analysis. However, progress in the field is hindered by the lack of systematic benchmarks that compare machine learning methods under realistic conditions, particularly sensor drift, a known but rarely quantified failure mode. Most existing studies rely on small, private datasets with inconsistent protocols, rendering results non-comparable and slowing progress. We introduce Breath-Dx, the first comprehensive benchmark of time series classification methods for breath-based disease screening. Our work leverages the Scent of Health (S-OH) dataset, the largest public clinical eNose collection to date, comprising 1,234 patients across nine diagnostic groups, each providing a 17-channel multivariate time series with explicit temporal train/test splits that account for sensor drift. We systematically evaluate 10 methods spanning four families: feature-based tabular learners, convolution-based models, graph-based, and time series architectures. All methods degrade significantly under temporal validation (0.05-0.12 AUC drop compared to random cross-validation), confirming that drift embeds a strong temporal signal. Under this realistic evaluation, the best methods achieve ROC AUC of 0.74-0.76 for some lung conditions, though others remain near chance. Recurrent architectures show the most consistent performance across diseases, while specialized time series methods achieve the highest peak results. Demographic confounders matter: breath signals provide independent diagnostic value for some conditions but add little beyond age for others. We release the S-OH dataset, all temporal splits, evaluation protocols, and code to enable reproducible research and accelerate progress in clinical breathomics.

cs.LG · cs.AI