跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2505.07687 · v5

FermatSyn: SAM2-Enhanced Bidirectional Mamba with Isotropic Spiral Scanning for Multi-Modal Medical Image Synthesis

首次提交 2025-05-12 23:51
版本更新 2026-10-26 15:11
雷达观测 2026-10-29 00:36
arXiv ↗PDF ↗

摘要

Multi-modal medical image synthesis is pivotal for alleviating clinical data scarcity, yet existing methods fail to reconcile global anatomical consistency with high-fidelity local detail. We propose FermatSyn, which addresses three persistent limitations: (1) SAM2-based Prior Encoder that injects domain-aware anatomical knowledge via LoRA$^{+}$ efficient fine-tuning of a frozen SAM2 Vision Transformer; (2) Hierarchical Residual Downsampling Module (HRDM) coupled with a Cross-scale Integration Network (CIN) that preserves high-frequency lesion details and adaptively fuses global--local representations; and (3) continuity constrained Fermat Spiral Scanning strategy within a Bidirectional Fermat Scan Mamba (BFS-Mamba), constructing an approximately isotropic receptive field that substantially reduces the directional bias of raster or spiral serialization. Experiments on SynthRAD2023, BraTS2019, BraTS-MEN, and BraTS-MET show FermatSyn surpasses state-of-the-art methods in PSNR, SSIM, FID, and 3D structural consistency. Downstream segmentation on synthesized images yields no significant difference from real-image training ($p{>}0.05$), confirming clinical utility. Code is available at https://github.com/exsinger-hub/ FermatSyn.

作者备注:MICCAI 2026

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v5 · 2026-10-26 15:11 · 最新观测版本

FermatSyn: SAM2-Enhanced Bidirectional Mamba with Isotropic Spiral Scanning for Multi-Modal Medical Image Synthesis

Multi-modal medical image synthesis is pivotal for alleviating clinical data scarcity, yet existing methods fail to reconcile global anatomical consistency with high-fidelity local detail. We propose FermatSyn, which addresses three persistent limitations: (1) SAM2-based Prior Encoder that injects domain-aware anatomical knowledge via LoRA$^{+}$ efficient fine-tuning of a frozen SAM2 Vision Transformer; (2) Hierarchical Residual Downsampling Module (HRDM) coupled with a Cross-scale Integration Network (CIN) that preserves high-frequency lesion details and adaptively fuses global--local representations; and (3) continuity constrained Fermat Spiral Scanning strategy within a Bidirectional Fermat Scan Mamba (BFS-Mamba), constructing an approximately isotropic receptive field that substantially reduces the directional bias of raster or spiral serialization. Experiments on SynthRAD2023, BraTS2019, BraTS-MEN, and BraTS-MET show FermatSyn surpasses state-of-the-art methods in PSNR, SSIM, FID, and 3D structural consistency. Downstream segmentation on synthesized images yields no significant difference from real-image training ($p{>}0.05$), confirming clinical utility. Code is available at https://github.com/exsinger-hub/ FermatSyn.

查看此版本解读 →查看此版本原文 ↗