跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2509.19774 · v4

PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

首次提交 2025-09-24 13:54
版本更新 2026-11-23 23:03
雷达观测 2026-11-24 14:49
arXiv ↗PDF ↗

摘要

Electrocardiography (ECG) is the clinical gold standard for cardiovascular disease (CVD) assessment, yet continuous monitoring is constrained by the need for dedicated hardware and trained personnel. Photoplethysmography (PPG) is ubiquitous in wearable devices and readily scalable, but it lacks electrophysiological specificity, limiting diagnostic reliability. While generative methods aim to translate PPG into clinically useful ECG signals, existing approaches are limited by the misalignment of physiological semantics in generative models and the complexity of modeling in high-dimensional signals. To address these limitations, we propose PPGFlowECG, a two-stage framework that aligns PPG and ECG in a shared latent space using the CardioAlign Encoder and then synthesizes ECGs with latent rectified flow. We further provide a formal analysis of this coupling, showing that the CardioAlign Encoder is necessary to guarantee stable and semantically consistent ECG synthesis under our formulation. Extensive experiments on four datasets demonstrate improved synthesis fidelity and downstream diagnostic utility. These results indicate that PPGFlowECG supports scalable, wearable-first CVD screening when standard ECG acquisition is unavailable.

作者备注:Accepted at IEEE ICDM 2026 and awarded the Best Paper Award (Applied Track)

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v4,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v4 · 2026-11-23 23:03 · 最新观测版本

PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

Electrocardiography (ECG) is the clinical gold standard for cardiovascular disease (CVD) assessment, yet continuous monitoring is constrained by the need for dedicated hardware and trained personnel. Photoplethysmography (PPG) is ubiquitous in wearable devices and readily scalable, but it lacks electrophysiological specificity, limiting diagnostic reliability. While generative methods aim to translate PPG into clinically useful ECG signals, existing approaches are limited by the misalignment of physiological semantics in generative models and the complexity of modeling in high-dimensional signals. To address these limitations, we propose PPGFlowECG, a two-stage framework that aligns PPG and ECG in a shared latent space using the CardioAlign Encoder and then synthesizes ECGs with latent rectified flow. We further provide a formal analysis of this coupling, showing that the CardioAlign Encoder is necessary to guarantee stable and semantically consistent ECG synthesis under our formulation. Extensive experiments on four datasets demonstrate improved synthesis fidelity and downstream diagnostic utility. These results indicate that PPGFlowECG supports scalable, wearable-first CVD screening when standard ECG acquisition is unavailable.

查看此版本解读 →查看此版本原文 ↗