跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2512.15729 · v3

TinyMyo: a Tiny Foundation Model for Flexible EMG Signal Processing at the Edge

首次提交 2025-12-06 01:36
版本更新 2026-11-18 04:59
雷达观测 2026-11-19 19:08
arXiv ↗PDF ↗

摘要

Objective: Surface electromyography (EMG) is widely used in biomechanics, rehabilitation, prosthetic control, and human-machine interfaces. Generalization across subjects, recording systems, and acquisition protocols remains challenging. Existing EMG foundation models (FMs) have limited support for multiple downstream tasks and deployment on low-power devices. Methods: We introduce TinyMyo, a 3.6-million-parameter Transformer encoder pre-trained on public EMG datasets using self-supervised masked reconstruction. TinyMyo supports multiple tasks with minimal changes to the task-specific prediction head. Results: We evaluated TinyMyo on hand gesture classification, hand kinematic regression, speech production, and speech recognition. For gesture classification, TinyMyo outperformed previously reported EMG FMs, achieving accuracies of 87.98% on NinaPro DB5, 97.1% on UCI-EMG, and 96.6% on EPN-612. On the GAP9 ultra-low-power microcontroller, TinyMyo achieved an inference time of 0.785 s and consumed 44.91 mJ per inference at an average power of 57.18 mW. A 1.9-million-parameter variant processed 5 s and 1 s input windows in 0.496 s and 0.089 s, respectively. Conclusion: TinyMyo demonstrates that a compact, self-supervised EMG encoder can support multiple downstream tasks and run on a low-power microcontroller. Significance: To our knowledge, this is the first deployment of an EMG FM on an ultra-low-power microcontroller, opening a path to on-device motor intent decoding, neuromuscular assessment, and human-machine interaction.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v3,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v3 · 2026-11-18 04:59 · 最新观测版本

TinyMyo: a Tiny Foundation Model for Flexible EMG Signal Processing at the Edge

Objective: Surface electromyography (EMG) is widely used in biomechanics, rehabilitation, prosthetic control, and human-machine interfaces. Generalization across subjects, recording systems, and acquisition protocols remains challenging. Existing EMG foundation models (FMs) have limited support for multiple downstream tasks and deployment on low-power devices. Methods: We introduce TinyMyo, a 3.6-million-parameter Transformer encoder pre-trained on public EMG datasets using self-supervised masked reconstruction. TinyMyo supports multiple tasks with minimal changes to the task-specific prediction head. Results: We evaluated TinyMyo on hand gesture classification, hand kinematic regression, speech production, and speech recognition. For gesture classification, TinyMyo outperformed previously reported EMG FMs, achieving accuracies of 87.98% on NinaPro DB5, 97.1% on UCI-EMG, and 96.6% on EPN-612. On the GAP9 ultra-low-power microcontroller, TinyMyo achieved an inference time of 0.785 s and consumed 44.91 mJ per inference at an average power of 57.18 mW. A 1.9-million-parameter variant processed 5 s and 1 s input windows in 0.496 s and 0.089 s, respectively. Conclusion: TinyMyo demonstrates that a compact, self-supervised EMG encoder can support multiple downstream tasks and run on a low-power microcontroller. Significance: To our knowledge, this is the first deployment of an EMG FM on an ultra-low-power microcontroller, opening a path to on-device motor intent decoding, neuromuscular assessment, and human-machine interaction.

查看此版本解读 →查看此版本原文 ↗